Programming The User Setup - GRAUPNER S8474 Manual

Pdb + sbec module, voltage, current, capacity, telemetry
Table of Contents

Advertisement

Page 5



















Page 6


















Page 7




















Programming the User Setup

Page 1









Page 2











S8474_PDB_SBEC_V_1_jh
Max Power Voltage
Here you can set the alarm threshold for maximum voltage.
The alarm threshold can be set between 0 and 25.0 V in steps
of 0,1 V.
Factory setting: 17.5 V, Signal Tone: X
Max Current
Here you can set the first alarm threshold for maximum current.
The alarm threshold can be set between 0 and 150 A in steps
of 1 A.
Factory setting: 40 A, Signal Tone: W
Max used Capacity
Here you can set the alarm threshold for maximum consumed
capacity.
The alarm threshold can be set between 0 and 30000 mA in
steps of 10 mA.
Factory setting: 2000 mA, Signal Tone: V
In the "User Setup" the BEC voltage produced by the PDB +
SBEC Module is set.

Save Sensor: yes/no

After every setting in the page "Page 2" the data must be trans-
ferred to the PDB + SBEC Module. Select "yes" and push "Enter".
If you do not proceed as described, the new data will not be
saved.
Factory set
A factory reset will be done if you select "yes" and push "Enter".
All the values will be reset to the factory settings.
BEC Voltage
Here you set the BEC voltage.
The voltage can be set between 4,5 and 8 V.
In the following lines the BEC voltage will be shown.