General air-module 2-6 s with vario

Advertisement

33611 General Air-Module 2-6 S with Vario
Contents
1. Description.................................................................................................................................................................2
2. Warnings ...................................................................................................................................................................3
3. Mounting the Module in the Plane .............................................................................................................................4
4. Connection of sensors ...............................................................................................................................................5
5. Starting up .................................................................................................................................................................6
6. Operation ...................................................................................................................................................................6
6.1. Display LIPO CELL VOLTAGE ...............................................................................................................................7
6.2 Sensor 1/2 voltage...................................................................................................................................................8
6.3. Sensor 1/2 Temperature .........................................................................................................................................8
6.4. Vario Display ...........................................................................................................................................................9
6.5. RPM sensor / Fuel sensor ......................................................................................................................................9
7. Programming Warning thresholds ...........................................................................................................................10
7.2. Minimum Cell Voltage Sensor 1 (Page 3).............................................................................................................12
7.3. Maximum Cell Voltage Sensor 1 (Page 4)............................................................................................................12
7.4. Minimum Temperature Sensor 1 (Page 5) ............................................................................................................12
7.5. Maximum Temperatur Sensor 1 (Page 6) .............................................................................................................12
7.6. Minimum Cell Voltage Sensor 2 (Page 7).............................................................................................................13
7.7. Maximum Cell Voltage Sensor 2 (Page 8)............................................................................................................13
7.8. Minimum Temperature Sensor 2 (Page 9) ............................................................................................................13
7.9. Maximum Temperature Sensor 2 (Page 10) .........................................................................................................13
7.10. Maximum Current (Page 11) ..............................................................................................................................14
7.11. Maximum used Capacity (Page 12) ....................................................................................................................14
7.12. Minimum Voltage socket 1 (Page 13) .................................................................................................................14
7.13. Maximum Voltage socket 1 (Page 14) ................................................................................................................14
7.14. Minimum Altitude (Page 15) ...............................................................................................................................15
7.15. Maximum Altitude (Page 16) ..............................................................................................................................15
7.16. Sink rate per second (Page 17) ..........................................................................................................................15
7.17. Sink rate per 3 seconds (Page 18) .....................................................................................................................15
7.18. Climb rate per second (Page 19)........................................................................................................................16
7.19. Climb rate per 3 seconds (Page 20) ..................................................................................................................16
7.20. Minimum RPM (Page 21) ...................................................................................................................................16
7.21. Maximum RPM (Page 22) ..................................................................................................................................16
8. Setup Displays.........................................................................................................................................................17
8.1. Calibration of the temperature sensors ................................................................................................................17
8.2. Continous vario ....................................................................................................................................................18
8.3. Blade Number .....................................................................................................................................................19
8.4. Current Control ...................................................................................................................................................20
8.5. Settings and calibration of the precision fuel sensor (fuel settings)......................................................................22
9. Summary Signal tones ............................................................................................................................................25
10. Telemetry display ...................................................................................................................................................26
11. Firmware Update ..................................................................................................................................................27
12. Specifications General Air-Modul ..........................................................................................................................28
13. EG declaration of conformity .................................................................................................................................29
14. Environmental Protection Notes ............................................................................................................................29
15. Warranty ................................................................................................................................................................30
GRAUPNER/SJ GmbH - Postfach 1242 - 73230 Kirchheim/Teck - www.graupner.de
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HoTT 2.4 and is the answer not in the manual?

Questions and answers

Summary of Contents for GRAUPNER HoTT 2.4

  • Page 1: Table Of Contents

    9. Summary Signal tones ............................25 10. Telemetry display ..............................26 11. Firmware Update ..............................27 12. Specifications General Air-Modul ..........................28 13. EG declaration of conformity ..........................29 14. Environmental Protection Notes ..........................29 15. Warranty ................................30 GRAUPNER/SJ GmbH – Postfach 1242 – 73230 Kirchheim/Teck – www.graupner.de...
  • Page 2: Graupner Hott

    General Air-Module for the Graupner HoTT 2.4 system. If you do not have the Graupner HoTT 2.4 radio system this product will not work. This product is not com- patible with any other 2.4GHz radio system.
  • Page 3: Warnings

    It may be necessary to shorten the leads, and / or set a throttle pick-up delay, in order to prevent timing errors. Use only motors delivered by GM-Racing or Graupner/SJ which are designed for the intended range of voltages! Use only high performance batteries by Graupner/SJ or GM-Racing.
  • Page 4: Mounting The Module In The Plane

    Therefore Graupner Ltd cannot take on any liability for any loss, damage, or costs resulting from an incorrect use or operation of the product, or connected in any way with incorrect use or operation.
  • Page 5: Connection Of Sensors

    Connect any additional sensors to the corresponding sockets as shown in the illustration at the top. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 6: Starting Up

    After SETTING AND DATA VIEW have chosen, the „Lipo Cell Voltage“ display is available. The sensor dis- plays follow the transmitter (TX) and receiver (RX) displays, i.e. the „Lipo Cell Voltage“ display follows after the last display servo test (RX SERVO TEST). 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 7: Display Lipo Cell Voltage

    Single cell voltage of the LiXX-battery connected to socket 6 Min. Minimum single cell voltage of the LiXX-battery connected to socket 6 since the start Maximum single cell voltage of the LiXX-battery connected to socket 6 since the start 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 8: Sensor 1/2 Voltage

    Minimum/Maximum temperature of sensor 1 connected to socket 5 since the start Sensor 2 Current temperature of sensor 2 connected to socket 7 Min./Max. Minimum/Maximum temperature of sensor 2 connected to socket 7 since the start 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 9: Vario Display

    Current motor speed in revolutions per minute and the preset blade number Max. Maximum RPM since the start Min. Minimum RPM since the start Fuel Gauge Fuel Level since the start Fuel Usage Fuel Consumption since the start 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 10: Programming Warning Thresholds

    VARIO SENSOR and the selected Signal tone a - Z sounds. you can stop the warning at any time by pressing one of the buttons on the top of the SMaRt- BoX. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 11 2.5 and 4.2 V (0.1 V steps). Voltage/Cell 3.3V Factory setting: 3.3 V, Signal Tone: Q Warning Time : Repeat Time : Always The bottom line shows the current measured value. Signal Tone Min. Voltage : 0.000V 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 12: Minimum Cell Voltage Sensor

    6 threshold set between -20 and 200° C (1° C steps). Temperature : 100°C Factory setting: 100° C, Signal Tone: H Warning Time : Repeat Time : Always Signal Tone Sensor 1 00°C 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 13: Minimum Cell Voltage Sensor

    10 threshold set between -20 and 200° C (1° C steps). 100°C Temperature : Factory setting: 100° C, Signal Tone: I Warning Time : Repeat Time : Always Signal Tone Sensor 2 00°C 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 14: Maximum Current

    0 and 80.0 V (0.1 V steps). >Set Warning : page 14 30.0V Max. Voltage : Factory setting: 30.0 V, Signal Tone: X Warning Time : Repeat Time : Always Signal Tone Voltage 0.00V 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 15: Minimum Altitude

    Meter, warning threshold set between -500 and 0 m (based on the Always Repeat Time : starting altitude 0 m) Signal Tone Factory setting: 1 m/3 Sec., Signal Tone: B 0.0m Diff./ 3Sec. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 16: Climb Rate Per Second

    The warning threshold is adjustable from 0 to 200.000 rpm (1 blade) 7000 Maximum rpm : Warning Time : with 10 rpm steps. Always Repeat Time : Factory setting: 7000 rpm, Signal Tone: Y Signal Tone RPM ( 2 ) 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 17: Setup Displays

    < page 1 >User Setup page 1 >User Setup Save Sensor? Save to Sensor? Factory Set? Factory Set? INC + DEC Adjust Temperature page 2 >User Setup Sensor1 Temp: 30°C 30°C Sensor2 Temp: 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 18: Continous Vario

    Is the rate more than 2 m, the next higher note (B) sounds, etc. The actual climb or descent rate is displayed in the Vario screen alternately in the top row. This display responds faster than the „Diff.“- information the display below, so the values can differ. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 19: Blade Number

    33516) the propeller / rotor has to get the correct rpm. In addition, you can set the minimum engine speed at which the alarm should be triggered. Blade number: adjustable from 1 to 6 blades 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 20: Current Control

    • Use a three-core lead to connect the socket CI on the General Air module to the recei- ver socket to which the electronic speed controller would usually be connected. • Current control can be activated and disabled from the transmitter: for this function you need one vacant swit- 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 21 STOP. Once the motor current is below 40 A again, the module raises the throttle setting again to the value set by the throttle stick (1900us). 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 22: Settings And Calibration Of The Precision Fuel Sensor (Fuel Settings)

    Make sure that the polarity is cor- rect! (see illustration) General module: "Fuel" connector Fuel sensor: " connection socket" 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 23 The setting values shown in the table are for guidance only and may vary slightly due to production fluctuations, temperature and fuel composition. Every flow meter should therefore be calibrated once in its operating range. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 24 The setting values shown in the table are for guidance only and may vary slightly due to production fluctuations, temperature and fuel composition. Every flow meter should therefore be calibrated once in its operating range. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 25: Summary Signal Tones

    4: Max. voltage sensor 1 page 8: Max. voltage sensor 2 page 22: Maximum RPM page 16: Max. Altitude page 20: climb rate per 3 sec. page 19: climb rate per sec. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 26: Telemetry Display

    2:0.00 0.0V 0.0V 3:0.00 POWER-V 4:0.00 T1 +20°C T1 +20°C 12.5V 5:0.00 25.3A BATT2 6:0.00 BATT2 0.0V T2 +20°C 80.0 0.0V T2 +20°C 12500 The right third of the display is shown alternately. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 27: Firmware Update

    USB interface, Order No. 7168.6, the adapter lead, Order No. 7168.6A and a Y-cable Order No. 3936.11 which are available separately. The programs and files required for this are available from www.graupner.de in the Download area for the corresponding products.
  • Page 28: Specifications General Air-Modul

    200.000 rpm resolution 10 rpm Fuel display 0 %, 25 %, 50 %, 75 %, 100 % The current version of this manual is available on the Graupner website www.graupner.de under Order No. 33611 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 29: Eg Declaration Of Conformity

    If you don’t know the location of your nearest disposal centre, please enquire at your local council office. 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 30: Warranty

    Kirchheim/Teck, Germany guarantees this product for a Pour adresses des points de service situés en dehors de l'Allemagne s'il vous plaît se référer à www.graupner.de/fr/. period of 24 months from date of purchase. The guarantee applies only to such material or operational defects witch are present at the time of purchase of the product.
  • Page 31 33611 General Air-Modul - Graupner HoTT 2.4...
  • Page 32 Graupner/SJ GmbH Henriettenstraße 96 D-73230 Kirchheim/Teck Germany www.graupner.de Änderungen sowie Liefermöglichkeiten vorbehalten. Lieferung durch den Fachhandel. Bezugsquellen werden nachgewiesen. Für Druckfehler kann keine Haftung übernommen werden. Specifications and availability subject to change. Supplied through specialist model shops only. We will gladly inform you of your nearest supplier. We accept no liability for printing errors.