Blodgett KTT-G Series Installation Operation & Maintenance page 22

Gas table top tilting kettle
Table of Contents

Advertisement

20
OM-KTT/KTC-G
Maintenance
19.
Removal of water level probe
a.
Tilt kettle 90° and remove bottom cover.
b.
Remove yellow wire from probe.
c.
Unscrew probe from kettle jacket.
20.
Installation of water probe
a.
Apply Teflon tape to probe threads.
b.
Screw probe into kettle jacket and torque to 150 in-lbs.
c.
Attach yellow wire to probe.
d.
Reinstall bottom cover.
e.
Check water level.
f.
Remove air from jacket.
21.
Removal of pressure switch
a.
Tilt kettle a full 90°.
b.
Remove bottom cover.
c.
Unplug red and white wires from switch.
d.
Using a 9/16 open end wrench, carefully unscrew the pressure
switch from the 90° elbow.
22.
Installation of pressure switch
a.
Hand start the pressure switch into the 90° elbow.
b.
Using a 9/16 wrench, tighten the switch to 90 in-lbs.
c.
Reattach the red and white wires to the switch.
d.
Reinstall bottom cover.
e.
Check water level.
f.
Remove air from jacket.

Advertisement