AGFEO AS 31 ST Installation Instructions Manual
AGFEO AS 31 ST Installation Instructions Manual

AGFEO AS 31 ST Installation Instructions Manual

Hide thumbs Also See for AS 31 ST:

Advertisement

Quick Links

Business-Line: AS 31 ST
AS 32
- Installation
1 - 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the AS 31 ST and is the answer not in the manual?

Questions and answers

Summary of Contents for AGFEO AS 31 ST

  • Page 1 Business-Line: AS 31 ST AS 32 - Installation 1 - 1...
  • Page 2: Safety Notes

    S0 bus (AS 32) that you are also allowed to operate directly on the ISDN The telephone system has a general network. Two digital AGFEO system connection permit (Germany: AAE). telephones can be also connected to every Safety notes ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢...
  • Page 3: Installation

    (mains lead approximately 1.2 m long). containing excessive amounts of dust or in locations where it may be splashed - For configuration of the PBX AS 31 ST via with water or chemicals. the serial PC / printer interface (RS 232C), it must be possible to place a laptop or a - Ambient temperature: 5°C to 40°C...
  • Page 4 Opening the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ Caution: mortal danger ! Press with a screwdriver onto the tabs in the slits on the connection side of the housing. Before removing the inner cover, pull out The cover is released and you can detach it. the 230 V mains plug to switch off the telephone system.
  • Page 5 Securing the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ Stone drill: 6 mm, hole depth: 40 mm - Mark the mounting holes (M). Wood drill: 3.5 mm, - When marking the mounting holes, make Hole depth: 35 mm sure that there are no concealed pipes or cables at these points (gas, water and - Drive in the dowels until they are flush power lines etc.).
  • Page 6 Drawing 2: Pin assignments 1 - 6...
  • Page 7 External fixed S0 port (Western socket) ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ Point-to-point connection Terminators for the external S0 port For the point-to-multipoint connection, the You can only connect one ISDN telephone two switches S400 and S401 for the 100 system to an ISDN point-to-point connec- Ohm terminators, which must belong to tion.
  • Page 8 Connecting analog users ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ You may connect all analog terminals to the telephone system that you are also permit- System telephones ted to operate on the analog telecommuni- Connect system telephones by four wires to cations network. the Vario ports by connecting them to the La and Lb wires (speech wires) and the Da a/b terminals are: and Db wires (data wires;...
  • Page 9 You connect this bus via a 4 wire srew clip. ISDN terminals: You need the following material to install an - AGFEO system telephones digital internal S0 port: - ISDN telephones - Telecommunications cable; we recom- - ISDN cards mend the cable type I-Y (St) Y 2 x 2 x 0.6...
  • Page 10 Connecting a door hands free unit (TFE) ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ TFE - interface conforming to the 4-wire TFE Maximum contact load-carrying capacity: specification FTZ 123 D12 for the connec- 30 VDC/1 A or 123 VAC/0.5 A. tion of door stations with amplifiers. You can only activate the door opener from a terminal of the telephone system Connections: (drawing 2)
  • Page 11 Switching relays ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ You can put the relays to diverse use as indi- nal or external telephone. You can also as- vidual switching relays R1 to R4 for other sign internal phone numbers to the relays in functions. For example, you can use them to order to include them in the ringing distri- connect a door hands free unit (TFE), an ad- bution settings, e.g.
  • Page 12 Connecting a printer for printing connection charges ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ To print out connection records, the printer You can connect any printer to the tel- must be on all the time and must be con- ephone system’s RS 232C interface to print nected to the telephone system.
  • Page 13 Commissioning You have installed the telephone system. - Once the telephone system has been Now, only a few operations are necessary switched on, you can immediately make before you are able to make telephone calls. internal and external telephone calls. When an external subscriber calls, all con- - Connect terminals.
  • Page 14: As -Delivered State

    - Own tariff units factor: 0,12 DM (decade 1 set) and terminal types - Base factor (network operator factor): AS 31 ST: 11 to 18, telephones 0, 12 DM AS 32: 11 to 20, telephones - Cleardown at cost limit: off...
  • Page 15: Technical Data

    Technical data Housing dimensions 32 x 25 x 8.5 cm (width x height x depth) Weight 2,54 kg Ambient temperature - Operation 5 ºC to 40 ºC - Storage -25 ºC to +70 ºC Mains connection 230 V AC, +6%/-10%, 50 Hz - Power consumption 30 VA (full load) External fixed S0 access...
  • Page 16 Telecommunications equipment 73/23/EWG Low-voltage devices 89/336/EWG Electromagnetic compatibility This is why your telephone system bears the CE mark. Ident. No. 529 273 AGFEO GmbH & Co. KG Modifications and errors reserved. Gaswerkstr. 8 Printed in Germany D-33647 Bielefeld 0992 Internet: http://www.agfeo.de...