Page 1
CAL. 7T92 & YM92 CHRONOGRAPH TIME/CALENDAR Hour, minute and small second hands Date displayed in numerals STOPWATCH Measures up to 12 hours in 1/20 second increments. Split time measurement...
Page 2
DISPLAY AND CROWN/BUTTONS STOPWATCH 1/20-second hand Minute hand Hour hand CROWN Small second hand Date STOPWATCH second hand STOPWATCH hour hand STOPWATCH minute hand b: First click c: Second click a: Normal position...
SCREW DOWN CROWN [for models with screw down crown] Unlocking the crown 1 Turn Crown counterclockwise until you no longer feel the threads turning. 2 Crown can be pulled out. Locking the crown 1 Push Crown back in to normal position. 2 Turn Crown clockwise while pressing it lightly until tight.
SETTING THE TIME AND ADJUSTING THE STOPWATCH HAND POSITION This watch is so designed that: 1) time setting and 2) stopwatch hand position adjustment are both made with the crown at the second click position. Once the crown is pulled out to the second click, be sure to make the above adjustments at the same time.
1) TIME SETTING Hour hand Minute hand Turn to set the hour CROWN and minute hands. Small second hand * It is recommended that the hands be set to the time a few minutes ahead of the current time, taking into consideration the time required to adjust the STOPWATCH hand position if necessary.
Page 6
STOPWATCH 1/20-second hand STOPWATCH second hand STOPWATCH STOPWATCH hour hand minute hand Press for 2 seconds to select the STOPWATCH hand(s) to be adjusted. Selection of the hand(s) to be adjusted can be made in the following order by pressing button A for 2 seconds. STOPWATCH STOPWATCH STOPWATCH...
Page 7
Press repeatedly to set the selected STOPWATCH hand(s) to the “0” position. * The hand(s) move(s) quickly if button B is kept pressed. * After all the adjustments are completed, check that the hour and minute hands for time display indicate the current time. CROWN Push back in to normal position in accordance with a time signal.
SETTING THE DATE Before setting the date, be sure to set the time. CROWN 1 Pull out to first click. 2 Turn clockwise until the desired date appears. 3 Push back in to normal position. Date...
Page 9
STOPWATCH The stopwatch can measure up to 12 hours in 1/20-second increments. When the measurement reaches 12 hours, the stopwatch automatically stops counting. STOPWATCH second hand STOPWATCH Start / Stop / Restart 1/20-second hand Reset / Split /Split release STOPWATCH minute hand STOPWATCH hour hand Ex.: 2 hours, 30 minutes and 10.85 seconds...
Page 10
Movement of the STOPWATCH 1/20-second hand After the stopwatch is started, the STOPWATCH 1/20-second hand moves for about 10 minutes and automatically stops at the “0” position. When the measurement is stopped or split time is measured, it moves to indicate the elapsed 1/20 seconds.
Page 11
Split time measurement SPLIT START SPLIT STOP RESET RELEASE Measurement of two competitors FINISH TIME FINISH TIME START RESET OF 1ST COMPETITOR OF 1ST COMPETITOR FINISHES COMPETITOR...
Page 12
TACHYMETER [for models with tachymeter scale on the dial] To measure the hourly average speed of a vehicle [ Ex. 1 ] Use the stopwatch to determine how many seconds it takes to go 1 km or STOPWATCH 1 mile. second hand: 40 seconds Tachymeter scale indicated by...
Page 13
“90” (tachymeter scale figure) x 2 (km or mile) = 180 km/h or mph “90” (tachymeter scale figure) x 0.5 (km or mile) = 45 km/h or mph To measure the hourly rate of operation [ Ex. 1 ] Use the stopwatch to measure the STOPWATCH second hand: time required to complete 1 job.
NOTES ON OPERATING THE WATCH SETTING THE TIME AND ADJUSTING THE STOPWATCH HAND POSITION When the stopwatch is or has been measuring or is stopped, if the crown is pulled out to the second click, it will automatically reset the STOPWATCH hands to “0”. [TIME SETTING] When setting the hour hand, be sure to check that AM/PM is correctly set.
When the battery expires, be sure to replace it as soon as possible to prevent any malfunction. We recommend that you contact an AUTHORIZED PULSAR DEALER for battery replacement. After the battery is replaced with a new one, set the time/calendar and adjust the stopwatch hand position.
Page 16
* The watch remains accurate while the small second hand is moving at two-second intervals. WARNING Do not remove the battery from the watch. If it is necessary to take out the battery, keep it out of the reach of children.
Page 17
If the watch becomes wet, we suggest that you Water resistance (10 bar/15 bar/20 bar)* have it checked by an AUTHORIZED PULSAR If “WATER RESISTANT 10 BAR”, DEALER or SERVICE CENTER. “WATER RESISTANT 15 BAR”...
Page 18
* Before using the water resistance 5, 10, 15 or 20 bar watch in water, be sure the crown is pushed in completely. Do not operate the crown when the watch is wet or in water. If used in sea water, rinse the watch in fresh water and dry it completely.
MAGNETISM CARE OF CASE AND BRACELET To prevent possible rusting Your watch will be adversely of the case and bracelet affected by strong magnetism. caused by dust, moisture and Keep it away from close p e r s p i r a t i o n , w i p e t h e m contact with magnetic objects.
Need help?
Do you have a question about the 7T92 and is the answer not in the manual?