Cleaning Accessories - EdilKamin PELLINSERT 54 Installation, Use And Maintenance Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
OPTIONAL:
REMOTE TELEPHONE IGNITION (code 281900)
The insert can be remote ignited by connecting a telephone combiner to the electronic board (contact a Dealer).

CLEANING ACCESSORIES

GlassKamin
Ash vacuum cleaner
CHECK LIST
To be integrated with a complete reading of the technical board
Installation and commissioning
• Installation by Dealer that released warranty and maintenance manual.
• Room ventilation.
• The smoke channel/chimney flue only receives the insert discharge.
• The smoke channel (Pellinsert connection/chimney flue) has: • maximum 2 curves – maximum 2 metres horizontal
• Combustion chamber outside the backflow area.
• The chimney flue is created with suitable materials (stainless steel recommended).
• In crossing any flammable materials (e.g. wood), all precautions have been taken to avoid fire.
• presence of air circulation grills (36 x 9 cm) supplied on counter-hood.
Use
• Good quality, dry pellets used (max. moisture content 8%).
• The combustion chamber and ash compartment are clean.
• Glass must always be cleaned cold.
• The hatch must be properly closed.
• The combustion chamber must be properly inserted in the specific compartment.
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, empty the combustion chamber prior to repeating ignition.
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents