1. Use the Lamp Status Display to verify which lamp (1 or 2)
requires replacement.
2. Press the Side Control ON/STANDBY button twice to switch
the projector OFF. Let the projector cool for at least 45
minutes (READY indicator will be green).
3. Switch the Main ON/OFF Switch to OFF and unplug the AC
power cord from the AC outlet.
4. Loosen the lamp cover screw and slide the lamp cover away
from the projector. Then lift the cover until it locks into place
in the open position.
5. Loosen the 2 screws securing the lamp to be replaced and pull
the lamp up by grasping the handle.
6. Install the new lamp and make sure the lamp is properly
seated. Tighten the 2 screws.
7. Close the lamp cover and tighten the screw.
8. Connect the AC power cord to the projector and switch the Main ON/OFF Switch to ON.
9. Press the ON-STANDBY button to switch the projector ON.
10. Reset the Lamp Replacement Counter (see instructions below).
result in malfunctions, fire hazard, or other possible accidents.
NOTE: To maintain picture quality (better balance of color and brightness on entire screen), we
recommend replacing both lamps at one time.

RESETTING THE LAMP COUNTER

Make sure the Lamp counter is reset after a lamp is replaced. When the Lamp counter is reset, the
LAMP 1/ REPLACE or LAMP 2/REPLACE indicator will switch off and the Lamp replacement icon
will disappear.
1. Press the MENU button on the side-control to display
the On-Screen Menu. Use the Point
move the red frame pointer to the Setting Menu icon.
2. Use the Point
to Lamp counter and then press the Select button. A
dialog box appears. Select a lamp to display "Lamp
replacement counter Reset?". Select [Yes] to continue.
3. In the confirmation dialog box,select [Yes] to reset the
Lamp counter.
NOTE: Do not reset the Lamp counter without replacing a
lamp.