Festo MS6-SFE-F5-AGD Series Operating Instructions Manual page 49

Flow sensor
Table of Contents

Advertisement

Available languages

Available languages

MS6−SFE−...
5. Set the security code with the UP/DOWN button (0 = no protection).
6. In order to confirm, press the Edit button.
The MS6−SFE−... is in the RUN mode again.
Tip:
Keep the security code in a safe place. If you forget the security code
see section 6.
MINMAX mode
Shows the lowest and highest flow values up to the time of actuation.
Display minimum/maximum values
In order to activate the MINMAX mode, press buttons A and B simultaneously.
S
The lowest flow value up to this moment will then be displayed (min /F.Lo).
Press buttons A and B again simultaneously. The maximum flow value up to
S
this moment will then be displayed (max /F.Hi).
Press buttons A and B again simultaneously. The program then returns to the
S
RUN mode.
Reset the minimum/maximum value memory
Hold the A and B buttons pressed down longer than 2 seconds or switch off the
S
supply voltage.
Festo MS6−SFE−... 0507NH English
49