Festo MS6-SFE-F5-AGD Series Operating Instructions Manual page 47

Flow sensor
Table of Contents

Advertisement

Available languages

Available languages

MS6−SFE−...
b) Setting the switching functions
Flow measurement
(Out A/Out B)
Only with Out A:
When [Cons] flashes, select switching
S
mode [Flow] (with the UP/DOWN
button. [Flow] flashes.
In order to confirm the switching
S
mode [Flow], press the Edit button.
4. Select desired switching function
(threshold value/window comarator)
with the UP/DOWN button.
5. In order to confirm, press the Edit
button.
6. Set the switching point (SP or SP.Lo)
with the UP/DOWN button.
7. In order to confirm, press the Edit
button.
With switching function Window
comparator:
Set the value (SP.Hi) with the
S
UP/DOWN button.
In order to confirm, press the Edit
S
button.
8. Set the hysteresis (HY) with the
UP/DOWN button.
9. In order to confirm, press the Edit
button.
10. Select switching characteristic
[no/nc] with the UP/DOWN button.
11. In order to confirm, press the Edit
button.
The MS6−SFE−... is in the RUN mode again.
Fig. 14
Festo MS6−SFE−... 0507NH English
Consumption measurement
(only Out A)
Only if [Flow] flashes:
4. Select switching mode [Cons]
(consumption) with the UP/DOWN
button.
[Cons] flashes.
5. In order to confirm the switching
mode [Cons], press the Edit button.
6. Select physical unit with the
UP/DOWN button.
7. In order to confirm, press the Edit
button.
8. Set the consumption impulse (CI) with
the UP/DOWN button.
9. In order to confirm, press the Edit
button.
10. Select switching characteristic
[no/nc] with the UP/DOWN button.
11. In order to confirm, press the Edit
button.
47