Summary of Contents for Bibby Sterilin Stuart SW5

  • Page 1 Flocculator Instructions for use Version 1.1...
  • Page 2 Pre-set selector Speed control Display Mains on/off Lamp on/off Press to set Paddle Lamp Fig 1 SW5 sti rri ng lam p m ain s rp m sp ee d va r of f of f of f Fig 2 Control panel...
  • Page 3: General Description

    If the equipment is not used in the manner described in this manual the protection provided General Description by the equipment may be impaired. The Stuart SW5 Flocculator is designed to ensure Electrical Installation repeatable conditions between samples during water and sewage flocculation tests.
  • Page 4: Operation

    Maintenance & Servicing Pre-set selector: This three way switch allows selection of either variable speed (VAR), or one of the two pre-set speeds (P1 and P2). WARNING: Ensure the unit is disconnected from the mains electricity supply before Speed controller: This knob controls the paddle attempting maintenance or servicing.
  • Page 5: Warranty

    Warranty Bibby Scientific Ltd warrants this instrument to be free from defects in material and workmanship, when used under normal laboratory conditions, for a period of three (3) years. In the event of a justified claim, Bibby Scientific Ltd will replace any defective component or replace the unit free of charge.
  • Page 6 Notes...
  • Page 7 in practice. Where there is a possibility that injury, These products meet the relevant EC damage or loss might occur if equipment malfunctions harmonised standards for radio frequency due to radio frequency interference, or for general advice interference and may be expected not to before use, please contact the Service Department of interfere with, or be affected by, other equipment with Bibby Scientific Ltd.
  • Page 8: Inspection Report

    INSPECTION REPORT MODEL ELECTRICAL SAFETY ❏ ✓ 1. Earth continuity ❏ ✓ 2. Insulation ❏ ✓ 3. Flash test FUNCTIONAL ❏ ✓ 1. Indicators ❏ ✓ 2. Speed ❏ ✓ 3. Visual acceptance QUALITY CONTROL INSPECTOR...
  • Page 9 Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk...