Avaya 3600 Series Configuration And Administration Manual page 55

Ccms ip and call server with ip telephone emulation
Hide thumbs Also See for 3600 Series:
Table of Contents

Advertisement

Avaya, Inc.
Message
Charge Complete
The WT is now fully charged.
Checking Code
WT is contacting the TFTP Server to
determine if it has a newer version of
software that should be downloaded.
Checking DHCP IP
The WT is retrieving DHCP
information from the DHCP server
CRC Code Error
The software which has been TFTP
downloaded has a bad redundancy
code check
Code Mismatch!
The software loaded into the WT is
incorrect for this model handset
DCA Timeout
The WT has detected a fault for
which it cannot recover, possibly due
to a failure to acquire any network.
Dest Unreachable
Unable to establish network
connectivity with the gatekeeper
DHCP Error (1-5)
DHCP Error 1
DHCP Error 2
DHCP Error 3
DHCP Error 4
DHCP Error 5
DHCP Lease Exp
y...y = DHCP Server IP address
yyy.yyy.yyy.yyy
DHCP is not responding to renewal
attempts (at least one renewal
succeeded)
21-300352, Issue 2, July 2005
Configuration and Administration—AVAYA 3616/3620/3626 WT
Avaya CCMS IP, Avaya Call Server, with Avaya 4612 IP Telephone Emulation
Description
Action
No action needed.
None, this message should only
last for approximately one second.
If message remains displayed,
power off and contact customer
support for a replacement handset.
None. This is informational only.
Try the download again, it is
possible the software was
corrupted during download. If the
error repeats, check that the
download image on the TFTP
server is not corrupted.
Verify the License Management
value is correct. Replace the
software image on the TFTP
server with software that is correct
for the handset model.
Turn the WT off then on again. If
error persists, contact OEM
Technical Support and report the
error.
Verify gatekeeper is running and
has network connectivity to WLAN
infrastructure.
The WT cannot locate a DHCP
server. It will try every 4 seconds
until a server is located.
The WT has not received a
response from the server for a
request to an IP address. It will
retry until a server is found.
The server refuses to lease the WT
an IP address. It will keep trying.
The server offered the WT a lease
that is too short. The minimum
lease time is 10 minutes but OEM
engineers recommend at least one
hour minimum lease time. The WT
will stop trying. Reconfigure the
server and power cycle the WT.
Failure during WEP Key rotation
process (proprietary feature).
The WT failed to renew its DHCP
lease, either because the DHCP
server is not running, or because
the configuration has been
changed by the administrator. The
WT will attempt to negotiate a new
Page 55