Addendum Section: Pressurizing Cooling Tank
The water should
already be turned OFF
and the power
disconnected.
Unit as it appears with
top removed
STEP 1
Unplug un-insulated water
line from water valve inlet
(quick-connect elbow
located left side of water
valve facing the front of
the cooler). Set tubing
aside (careful to not
contaminate water contact
end).
STEP 2
Unplug tubing from
quick-connect elbow
leading to cooling tank
inlet.