Installation - Blodgett 40GS-KLS Series Installation Operation & Maintenance

Gas short stationary floor kettle
Table of Contents

Advertisement

WARNING
THIS UNIT MUST BE INSTALLED BY
PERSONNEL WHO ARE QUALIFIED TO
WORK WITH ELECTRICITY AND PLUMBING.
IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE
TO THE EQUIPMENT. THE UNIT MUST
BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES.
NOTICE
TO AVOID DAMAGING PARTS OF THE
BURNER SYSTEM UNDERNEATH THE KETTLE,
LIFT THE UNIT ONLY BY THE RING BENEATH
THE OUTER PORTION OF THE BODY.
WARNING
DO NOT ATTACH THE UNIT TO A TYPE "B"
VENT. FAILURE COULD RESULT IN FIRE OR
PROPERTY DAMAGE.
CAUTION
DO NOT USE KETTLE WITHOUT SUPPLIED
FLUESTACK & ELBOW INSTALLED.
FLUE RISER, 17 INCHES HIGH MUST BE
ATTACHED HERE. NOT SUITABLE FOR
CONNECTION TO TYPE B GAS VENT.
CAUTION
DO NOT CONNECT ANY PIPING TO THIS
PRESSURE RELIEF VALVE. IT MUST BE FREE
TO VENT STEAM AS NEEDED. ELBOW SHOULD
POINT DOWN TOWARD FLOOR. IMPROPER
INSTALLATION WILL VOID WARRANTY!
DANGER
ELECTRICALLY GROUND THE UNIT
AT THE TERMINAL PROVIDED. FAILURE TO
GROUND UNIT COULD RESULT IN
ELECTROCUTION AND DEATH.
The unit should be installed in a ventilated room for efficient performance. items
which may obstruct or restrict the flow of air for combustion and ventilation must be
removed. The area directly around the appliance must be cleared of all combustible
materials.
1.
Installation requires connection with gas and electrical services. See items 8 to
14 for details.
2.
To protect the unit from damage, leave it on the shipping pallet until the time of
installation. When installation is to begin, cut the straps holding the kettle, and
hoist the kettle straight up off the skid.
3.
Unit is for use only on non-combustible floors.
4.
Install the unit with a minimum clearance to combustible and non-combustible
construction of two inches at the sides and four inches at rear. Also leave enough
room for cleaning, maintenance, and service.
5.
The flue stack and flue elbow shipped with the kettle is the correct height and
shape to give maximum performance. Install the flue stack and flue elbow as
shown on the sketch at left.
Unit must be installed under a ventilation hood only. Installation of a ventilating
hood should comply with local codes and/or ANSI/NFPA-96 Latest Edition. Also,
local codes may require that the kettle be electrically interlocked to shut off
the gas supply and prevent the operation of the unit if the exhaust fan is not
operating or if the fire suppression system is activated. Failure to follow these
instructions can cause bodily injury and/or property damage.
6.
To level the unit, adjust leg length by turning the bullet feet.
7.
Make sure the water level is correct in the jacket, by confirming that the level
is between the marks on the gauge glass. If the water level is low, follow the
instructions under "Jacket Filling" in the "Maintenance" Section of this manual.
8.
To protect personnel from steam coming out of the pressure relief valve, the
open end of the elbow at the outlet must be directed down. If it is not, turn the
elbow to the correct position.
9.
Provide 115 VAC, 60 HZ, 1 PH, 15 AMP electrical service for standard unit. Unit
may be equipped for alternate electrical service of 208 VAC or 240 VAC, as
ordered. Use 1/2 inch waterproof conduit and waterproof connections. Observe
local codes and/or The National Electrical Code in accordance with ANSI/NFPA 70
- latest edition. AN ELECTRICAL GROUND IS REQUIRED. The electrical schematic
is located on the inside of the service panel.
In Canada, provide electrical service in accordance with the Canadian Electrical
Code, CSA C22.2 Part 1 and/or local codes.

Installation

OM-40GS-KLS
7