Description of unit
3.7 Technical data ProSpray 23
Voltage:
Max. current consumption:
Fuses:
Unit connecting line:
Acceptance capacity:
Max. operating pressure:
Volume flow at 120 bar
(12 MPa) with water:
Max. tip size:
Max. temperature of the
coating material:
Max. viscosity:
Filter insert
(standard outfitting):
Weight:
Special high-pressure hose: DN 6 mm, 15 m connecting
Dimensions (L x W x H)
Unit on high carriage:
Unit on low carriage:
Max. sound pressure level:
* Place of measuring: 1 m in distance from the unit and 1.6
m above the floor, 120 bar (12 MPa) operating pressure,
reverberant floor.

3.8 Transportation

Pushing or pulling the unit
Pull out the handle (Fig. 5, Item 1) until it will come no
further. Insert the handle – push the buttons (2) on the
spars, and then push in the handle.
2
ProSpray 23
230 V AC, 50 Hz
5 A
16 A time-lag
3 x 1.5 mm
2
– 6 m
1100 Watts
230 bar (23 MPa)
2.1 l/min
0.023 inch – 0.58 mm
43°C
25.000 mPa·s
mesh 60
25 kg
thread M 16 x 1.5
580 x 565 x 760 mm
820 x 430 x 545 mm
80 dB (A) *
1
2
g

3.9 Transportation in vehicle

Roll the high-pressure hose over the suspension device
at the handle.
Secure the unit with a suitable fastening.

4. Starting operation

4.1 High-pressure hose, spray gun and

separating oil

1. Screw the manometer combination (2) at the coating
material outlet (Fig. 6, Item 1).
2. Screw the transition socket (3) to the manometer
combination.
3. Screw the high-pressure hose (4) to the manometer
combination.
4. Screw the spray gun (5) with the selected tip onto the
high-pressure hose.
5. Tighten the union nuts at the high-pressure hoses
firmly so that coating material does not leak.