Phase 7.3.2 Coin Programming
Enter the programming mode by placing the switch on the
Phase 7 board in the up position while no cycle is in
progress. "Program Mode" will then be displayed.
Navigating Within The Programming Mode:
"Med" key to enter a program location.
"Hi-Temp" / "Lo-Temp" keys increase / decrease
program location.
"PAUSE" key rejects entry and moves to next program
location.
Changing A Parameter Value:
With parameter value displayed pressing "Lo Temp"
or "High Temp" changes the parameter value.
"Med" key must be pressed to accept a new parameter.
Typical Programming Example
Change a single coin acceptor from factory setting to yield
20 minutes for $.50, $.50 as the minimum amount to start,
and no differential in regard to temperature key selection.
Settings: Time for Amt to Start (PL03, PL04, PL05) ....... 20
Left Coin Denomination (PL06) .................... $ .25
Amount to Start (PL06) ................................. $ .50
Clearing Coin Credit
With no cycle in progress and program switch down, hold
"PAUSE" while pressing HI three times, LO twice, and MED
once. "Clear Credit?" will appear. Press any key to complete.
36
Accessing and Clearing Coin Vault Total
Enter program mode by switching program switch (up) while no
cycle is in progress.
Press HI – "Coin Vault total is $XXX" will appear.
Press HI – "Clear Coin Vault Total?" will appear.
Press MED to clear this amount or PAUSE to leave as is.
Hot Keys
In the Coin Mode Hot Keys are enabled while in a cycle by
placing the program switch in the up position.
In Free Mode Hot Keys are always enabled.
HI – Remaining credit – coin mode / remaining time – free mode.
MED – Temps – Exhaust / left, S.A.F.E. / right, Axial / middle
(Axial dryer).
LO – Tumbler RPM.
S.A.F.E. TEST: Switch to program mode. Press and hold the
"PAUSE" key until prompted to press MED to open the water.
L.C.D. Operating Messages
When display reads "Out of Order" pressing LO displays one of
the messages listed below:
MODEL FAULT – Wrong model selected at PL01/3rd position.
SAIL SWITCH CLOSED FAULT – Sail switch closed before
starting.
SAIL SWITCH OPEN FAULT – Sail switch failed to close after
starting.
BURNER HI-LIMIT FAULT – Oven thermostat switch has
opened.
EXHAUST HI-LIMIT FAULT – Tumbler thermostat switch has
opened.
BURNER CONTROL FAULT – No gas valve signal – Bad DSI unit.
IGNITION FAULT – No flame ignition detected thru all retries.
FLAME FAULT – Flame detected at ignition but failed later.
CLEAN LINT – Due to failure to clean out lint.
CHECK CONTROL BOARD FUSE #2 – Fuse 2 on Phase 7
board is open.
EXHAUST / AXIAL PROBE FAULT – Indicated probe has failed.
ROTATION SENSOR FAULT – Rotation sensor or tumbler drive
has failed.
EXHAUST HI-TEMP FAULT – Overheating condition has
occurred.
BURNER PURGE FAULT – Gas return signal before heat output.
When display reads "Out of Order" pressing and holding the
"PAUSE" key for 3-seconds clears the out of order message
provided the out of order condition has been corrected.
"S.A.F.E. System Disabled"
In Coin Mode hold "PAUSE" and "LO" keys down together to
display one or the following causes:
OPEN / SHORTED THERMISTOR – Probe or probe circuit bad.
OPEN / SHORTED WATER VALVE – Water valve or circuit bad.
WATER NOT CONNECTED – No water pressure at solenoid
valve.
"S.A.F.E. System (was) Activated"
Indicates the S.A.F.E. system is active or was active because a
fire was detected. The buzzer sounds at a fast pace while the
system is active.
A service call to your local dealer is required to reset the
microprocessor controller (computer). Qualified personnel will
inspect the dryer and, if it is found to be safe for operation, reset
the control.