Set the pump unit on the base and adjust the
nozzles. Anchor bolts must be cast with the
foundation.
If vibrations are transmitted to the foundation from
adjoining components, it must be guarded through
adequate vibration damping padding (vibrations
from outside can impair the bearing).
To
prevent
vibrations
adjoining components, the foundation should be
laid on a suitable insulating base.
The size of these insulating pads will vary,
depending
on
therefore be determined by an experienced
specialist.

5.2 Connection of Piping to the Pump

The pump must not be used as fixed point for
the piping. The permitted piping loads must not
be exceeded, refer to chapter 3.7.
5.2.1 Suction and discharge pipe
The pipes must be of a size and design that liquid
can flow freely into the pump and that the pump
functions without problems. Particular attention is
to be paid to ensuring that suction pipes are
airtight and that the NPSH values are observed.
Under suction lift condition the suction pipe lays in
the horizontal section towards the pump so that it
is slightly inclined upwards so that no air traps
occur. Do not install fittings or elbows right before
the suction nozzle.
Piping for direct installation of LR-, LMR-, LRZ- or
LMZ-pumps must show adequate firmness. Keep
in mind vibration insulation (see chapter 5.1).
When laying the pipes, make sure that the pump
is accessible for maintenance, installation and
disassembly.
Notice "Permitted Forces on Flanges" (chapter
3.7).
Before connecting up to pump: remove protective
coverings from suction and discharge branches.
Before starting up, the pipe system, fittings and
equipment must be cleaned to remove weld
spatter, scale etc. Any pollutants are to be
completely removed from pump units that are
directly or indirectly connected to drinking water
systems before being installed and taken into use.
To protect the shaft sealing (especially mechanical
seals)
against
recommended that a sieve, 800 micron, is
installed in the suction / intake pipe when the
motor is being started up.
If the pipe system is tested with the pump
installed, do not exceed the maximum permitted
casing pressure of the pump and/or shaft sealing
(see data sheet).
When emptying the pipe after the pressure test,
make sure that the pump is treated properly
(danger of rust and problems when starting up).
5.2.2 Additional connections LR, LRZ
The following additional connections are available:
being
transmitted
circumstances,
and
should
foreign
impurities,
Connection
E
L
M
5.2.3 Additional connections LMR, LMZ
The following additional connections are available:
to
Connection
E
L
M

5.3 Drive

The motor design of the pump is shown in the order
confirmation or on the motor name plate.
Note the Operating Instructions of the motor
manufacturer.
If in the process of repair a new motor is used, the
following has to be noticed:
The motor must comply with the requirements
stated
manufacturer, on demand).
Clean motor end and motor flange of new motor
carefully (remove varnish).

5.4 Electric Connection

Electrical connection work may only be carried
out by an authorised professional. The rules
and regulations valid for electrical technology,
especially
measures, must be observed. The regulations
it
is
of
the national power supply companies
operating in that area must also be observed.
Before starting work, check that the information on the
motor name plate is the same as the local mains
network. The power supply cable of the coupled drive
motor must be connected up in accordance with the
wiring diagram produced by the motor manufacturer.
A protective motor switch must be provided.
The direction of rotation must only be checked
when the pump is full. Dry running will cause
damage to the pump.
page 46
Model LR, LMR, LRZ, LMZ
Description
Pump drain
Air release
Pressure gauge
Description
Pump drain
Air release
Pressure gauge
in
sheet
1130.1A608
those
concerned
Dimension
R3/8"
R1/8"
R3/8"
Dimension
R3/8"
R1/4"
R1/4"
(order
from
with
safety