Bearings; Condensation; Approximate Value For Sound Pressure Level; Permitted Nozzle Loads And Torques At The Pump Nozzles - Xylem LOWARA LR Series Installation, Operation And Maintenance Instructions

Volute casing pumps
Table of Contents

Advertisement

Available languages

Available languages

Installation, Operating and Maintenance Instruction
3.3.2 General informations
The reuse of mech. seals that have already
been used for a longer time can lead to leaking
at the seal faces after reinstallation. Therefore
the replacement of the mech. seal with a new
one is recommended. The removed mechanical
seal can be reconditioned by the manufacturer
and serve as a replacement mech. seal.
3.3.3 Informations for the mounting
Pay
attention
Especially the seal faces must be clean, dry and
undamaged. Don't apply lubrication on the seal
faces of the mech. seal.
If a lubricant is provided with the replacement
mech. seal, you should use this.
Use mineral grease or oil only if you are
completely sure that the elastomers of the
mech. seal are oil resistant. Use no silicone.
Use only lubricants with which you are certain
that no dangerous reaction can occur between
the lubricant and the pumped medium.
Have all required parts prepared so that
assembly can be completed quickly. The
lubricants are only effective for a short time.
After that, the axial mobility and thus the
automatic adjustment of the elastomers is lost.
Never push elastomers over sharp edges. If
necessary, use mounting devices.
During installation, push the mech. seals with a
bellows in such a way that the bellows is
compressed and not stretched (danger of
tearing apart!).

3.4 Bearings

The motor bearings also serve as pump bearings. The
bearings
are
greased
maintenance-free.

3.5 Condensation

For motors which are used at high temperature
differences and places with extreme climatic situations
with high humidity, we recommend to use a motor with
anti-condensation heater to prevent the unit of
condensation water inside the housing. During motor
run the anti-condensation heater must not be switched
on.
to
the
utmost
cleanness!
for
life
and
are
3.6
Approximate
Pressure Level
Nominal
power
P
2950
N
-1
in kW
min
0,55
50,5
0,75
52,0
1,1
54,0
1,5
55,5
2,2
58,0
3,0
59,5
4,0
61,0
5,5
63,0
7,5
64,5
11,0
66,5
15,0
68,0
18,5
69,0
22,0
70,5
Sound pressure level L
from pump surface acc. to DIN 45635, part 1 and 24.
Room and foundation influences are not considered.
The tolerance for these values is ±3 dB(A).
Addition with 60 Hz-operation:
Pump alone: −
Pump with motor: +4 dB(A)
3.7 Permitted Nozzle Loads and Torques
at the Pump Nozzles ...
... following the Europump-Recommendation for
pump acc. to ISO 5199.
The data for forces and torques are only valid for static
piping loads and are valid for one nozzle. All values for
forces and torques refer to standard materials 0.6020
(Type LR) and/or 0.6025 (Type LMR, LMZ).
thus
page 43
Model LR, LMR, LRZ, LMZ
Value
Sound pressure level L
in dB(A)
pA
Pump alone
Pump + Motor
1450
2950
-1
-1
min
min
49,5
58,0
51,0
59,0
53,0
60,0
55,0
63,5
57,0
64,5
58,5
68,5
60,0
69,0
62,0
70,0
63,5
70,5
65,5
72,0
67,0
72,5
68,5
73,0
74,5
measured in 1 m distance
pA
for
Sound
1450
-1
min
52,0
54,0
55,5
57,0
59,0
61,0
63,0
65,0
67,0
69,0
70,0