Fig. 18 Hot Gas Bypass Valve Adjustment For Altitude; Fig. 19 Adjustment Angle - KAESER Aircenter SX 3 Service Manual

Screw compressor, sigma control basic
Table of Contents

Advertisement

Fig. 18
Fig. 19
Number: 9_6945 01USE
7
Initial Start-up
7.5
Hot gas bypass valve setting
Hot gas bypass valve adjustment for altitude
Installation altitude [ft]
H
Adjustment angle [°]
W
Hot gas bypass valve setting
1. Set the hot gas bypass valve according to the following illustrations and table.
Adjustment angle
➤ Take the adjustment angle from the table.
Altitude [ft]
Service manual
Screw compressor
Aircenter SX 3/7.5 SIGMA CONTROL BASIC
Adjustment angle [°]
41