5.7
Menu Extras
5.7.1
Submenu System Monitor
Via the menu System Monitor you receive all information about the status of the sys-
tem.
FIG. 45
Alarm counter
•
Under System alarms all possible system alarms are displayed. A red LED signals
a currently existing alarm. It is also displayed how often the alarm occured since the
unit has been switched on.
NOTE
If an alarm occurs several times or for a longer period of time, please disconnect the
system from electricity. If you switch on the unit and the alarm occurs again, there is
probably a hardware defect.
The following alarms are signalled:
– LCA (Logic Cell Array): The communication with a programmed component
is faulty.
– TIME KEEPER: The communication with the integrated time keeper is faulty.
– A/D D/A Converter 1: The communication with the first ADDA Converter is
faulty.
– A/D D/A Converter 2: The communication with the second ADDA Converter
is faulty.
– Temperature Sensor: The communication with the temperature sensor is
faulty.
– FLASH EPROM: The communication with the non-volantile memory is faulty.
Settings cannot be stored or read.
– MAIN EEPROM: The communication with the non-volantile memory is faulty.
Settings cannot be stored or read.
SYSTEM MONITOR
59