Follett Tempo UCD100A30-NF Operation And Service Manual page 5

Undercounter ice machine bin
Table of Contents

Advertisement

Water
WARNING!
Connect to potable water supply only.
§ Water Mineral Content:
– TDS: greater than 5 ppm (mg/l) but less than 400 ppm (mg/l)
– Hardness: Less than 200 mg/l (12 gpg)
§ Not recommended for use with softened water
§ Ingress Protection (IP) rating: IPX0 (no protection)
Clearances
§ Do not obstruct front grille air flow
§ 2.00" (5.08 cm) behind
Electrical
§ 115 V, 60 Hz, 1 phase, 2A.
§ Connect to dedicated 15 amp circuit, fuse or breaker.
§ 6' (1.8 m) cord with 90° rounded type B plug.
§ Must be grounded - requires 3-prong outlet. Do not remove ground.
§ A GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not
recommended for your unit because it could be prone to nuisance tripping.
Refrigeration
WARNING!
Do not damage the refrigerant circuit. Refrigerant can cause personal injury and/or damage dispenser.
§ Refrigerant
– R600a – 1.59 ounces (45 grams)
Tempo Undercounter Ice Machine Bin
5