English (GB)
Original installation and operating instructions.
CONTENTS
1.
Symbols used in this document
2.
System sizing
3.

Mechanical installation

4.

Electrical installation

5.
Startup
6.
Alarms
7.
Fault finding
8.
CMSP-PM1 Pictorial Diagram
Warning
Prior to installation, read this
document and the quick guide.
Installation and operation must comply
with local regulations and accepted
codes of good practice.
Warning
The use of this product requires
experience with and knowledge of the
product.
Persons with reduced physical,
sensory or mental capabilities must not
use this product, unless they are under
supervision or have b
the use of the product by a person
responsible for their safety.
Children must not use or play with this
product.
1. Symbols used in this document
Warning
If these safety instructions are not
observed, it may result in personal
injury.
Warning
If these instructions are not observed,
it may lead to electric shock with
consequent risk of serious personal
injury or death.
If these safety instructions are not
observed, it may result in malfunction
Caution
or damage to the equipment.
Notes or instructions that make the job
Note
easier and ensure safe operation.
2. System sizing
Warning
The system in which the CM Booster is
incorporated must be designed for the
maximum pump pressure.
The default setting will cause the pump
not to stop until it reaches its maximum
Caution
pressure.
2
Installation and operating instructions
een instructed in
3. Mechanical installation
Warning
Page
Before starting work on the CM Booster,
make sure that the power supply has
2
been switched off and that it cannot be
2
accidentally switched on.
2
4. Electrical installation
2
Warning
2
The electrical installation should be
2
carried out by an authorised person in
3
accordance with local regulations.
6
Check that the supply voltage and frequency
correspond to the values stated on the nameplate.
Warning
Before making any connections in the
unit, make sure that the power supply
has been switched off and that it
cannot be accidentally switched on.
The unit must be connected to an
external mains switch with a contact
gap of at least 3 mm in all poles.
As a precaution, the unit must be
connected to a socket with earth
connection.
We recommend to fit the permanent
installation with an earth leakage
circuit breaker (ELCB) with a tripping
current < 30 mA.
5. Startup
Do not start the pump until it has been
Caution
filled with liquid.
6. Alarms
If a dry-running alarm has been
activated, find the cause before the
Caution
pump is restarted in order to prevent
damage to the pump.