England's Stove Works CBEP Series Installation & Operation Manual page 38

Table of Contents

Advertisement

Available languages

Available languages

  
"E‐1" Code On Control Board  1. Vacuum bypass chip missing. 
Unit Shuts Down in 15‐20 
minutes with an "E‐2" code 
on control board. 
  
  
"E‐3" Code on Control Board 
(Overfire) 
  
  
"E‐4" Code on Control Board 
(Proof of flame lost) 
  
  
  
Notes: 
  
1. Whenever instructed to check/replace the vacuum sensor, also check for loose or cracked vacuum 
hose.  Also, be certain the vacuum measurement port in the firebox is kept clean (clean with a pipe 
cleaner or brush, do NOT use a vacuum to clean). 
  
2. To restart and clear an error code displayed on the control board, push the "ON" button and the 
unit should reset the error and restart. 
  
3. If you are uncertain about the meaning of an error code or have any questions at all, PLEASE 
contact Technical Support at (800)245‐6489. 
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
2. Loose exhaust fan set screw. 
1. Loose thermal sensor. 
2. Control board settings. 
3. Failure to light pellets. 
1. Convection (Room Air) blower 
failure. 
2. Partially blocked flue. 
3. Using fuel other than premium 
wood pellets. 
1. The hopper is empty. 
2. The hopper lid was left open 
too long during refueling. 
3. Component failure. 
4. Blower speed is set too high, 
cooling firebox too rapidly. 
  
 
 
 
38
2. Check set screw for tightness. 
1. Contact Technical Support. 
1. Check both sides of thermal 
sensor connection (at exhaust 
blower and at control board). 
2. Start stove on minimum Heat 
Range 5 to ensure a good fire is 
started. 
3. Check igniter for buildup or 
failure. 
1. Check convection blower for 
proper function, replace if 
necessary. 
2. Check flue for obstructions. 
3. Use ONLY premium wood 
pellets in this stove. 
1. Refill the hopper with pellets 
and restart the stove. 
2. Keep the hopper lid open for 
the shortest interval possible 
when refueling.  The safety switch 
stops the auger when the hopper 
lid is open. 
3. An auger motor failure or 
combustion motor failure can 
sometimes result in an "E‐4" code. 
4. Operate the stove with the 
blower speed and heat range at 
the same value. 
  
  
  
  