Symptoms - Husqvarna Automower 420 Workshop Manual

Hide thumbs Also See for Automower 420:
Table of Contents

Advertisement

Messages
Number
Message
MESSAGES WITHOUT ERROR CODE
NA
Needs manual charg-
ing
Ultrasonic problem (In
the Tools menu)
Wrong PIN
Next start hh:mm

8.2 Symptoms

The most commonly occurring symptoms are described below. All symptoms are grouped by the situation where they
occur most often.
1. Mowing
2. Searching
1191 - 001 -
Cause
The product is set to the
area operating mode.
Electronic problem: Ext board error (5)
Communication failed between the ul-
trasonic circuit board and the main cir-
cuit board:
No us extboard (1)
Com - Timeout (2)
Com - CMD rejected (3)
Com - InvalidMSG (4)
Com - Error counter (6)
Com - Main SW (8)
Continuous detection of obstacle due
to obstacle stuck on the sensors more
than 15 minutes or due to vibration:
Detection counter (/)
Wrong PIN code has been entered.
Five attemts are permitted, then the
keypad is blocked for 5 minutes.
The timer setting prevents the product
from operating.
The products clock is incorrect.
Action
Secondary
Put the product in the charging station.
This behaviour is normal and no further
action is required.
Check that the ultrasonic sensors with
its cables and the ultrasonic circuit
board are correctly installed.
Replace the ultrasonic sensors. Refer
To replace the ultrasonic sensors
to
450X/450XH/550/550H on page 30 .
Replace the ultrasonic circuit board.
Refer to
cuit board 450X/450XH/550/550H on
page 30 .
Check that the cable between the ultra-
sonic circuit board and the main board
is connected correctly. Replace if nec-
essary.
Replace the ultrasonic circuit board.
Refer to
cuit board 450X/450XH/550/550H on
page 30 .
Replace the main circuit board. Refer
To replace the main circuit board on
to
page 28 .
Check if the product is standing still in
front of an obstacle. Normal behavior,
move the product.
Check if there are leaves or other ob-
jects stuck on the ultrasonic sensors.
Check if the body is installed correctly .
Replace the ultrasonic sensors. Refer
To replace the ultrasonic sensors
to
450X/450XH/550/550H on page 30 .
Replace the ultrasonic circuit board.
Refer to
cuit board 450X/450XH/550/550H on
page 30 .
Enter the correct PIN code. Contact the
local dealer if you forgot the PIN code.
Change the timer settings.
Set the time.
3. Following the guide wire
4. Docking
To replace the ultrasonic cir-
To replace the ultrasonic cir-
To replace the ultrasonic cir-
Troubleshooting - 53

Advertisement