9. ERROR MESSAGES AND TABLE OF FAULTS

The anomalies are carried out on the display with an error code (e.g. E01).
The anomalies which can be reset by the user are shown with the
The anomalies which cannot be reset are carried out with the
To RESET the gas boiler, press
Figure 4
ERROR CODE
Description of FAULTS
E01
Gas supply fault
E02
Safety thermostat sensor tripped
Flue thermostat sensor tripped / Flue pressure
E03
switch tripped
E04
Safety error due to frequent fl ame loss
E05
Central heating NTC sensor fault
E06
Domestic Hot Water NTC sensor fault
E10
Water pressure LOW
Safety thermostat for low temperature system
E11
cuts in (if connected)
Boiler max temperature exceeded (probable
E25
pump jammed)
E35
Fault fl ame (parasitic fl ame)
Electronic board input frequency (Hz) incorrectly
E97
set
E98
Internal card error
E99
Internal card error
Note: when an anomaly occurs, the display background fl ashes with the error code.
To maintain effi cient and safe operation of your boiler have it checked by a Qualifi ed Service Engineer at the end of every
operating period.
Careful servicing will ensure economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily fl ammable cleaners (i.e.: gasoline,
alcohol, and so on). Always isolate the electrical supply to the appliance before cleaning it (see section 6).
925.492.2
BAXI - 925.200.1
button for at least 2 seconds.

10. SERVICING INSTRUCTIONS

symbol (e.g. fi gure 4).
symbol (e.g. fi gure 4.1).
Figure 4.1
CORRECTIVE ACTION
Press the
button (fi gure 1) for at least 2 seconds. If this
fault persist, call an authorised Service centre.
Press the
button (fi gure 1) for at least 2 seconds. If this
fault persist, call an authorised Service centre.
Call an authorised Service centre.
Call an authorised Service centre.
Call an authorised Service centre.
Call an authorised Service centre.
Check that the pressure in the system is as specifi ed. See
Section 5. If this fault persist, call an authorised Service cen-
tre.
Call an authorised Service centre.
Call an authorized Service centre.
Press the
button (fi gure 1) for at least 2 seconds. If this
fault persists, call an authorized Service centre
Change the frequency (Hz) setting.
Call an authorised Service centre.
Call an authorised Service centre.