Plan Vent System - Kenmore 110.70012 Series Use & Care Manual

Coin-operated commercial gas dryer
Table of Contents

Advertisement

Available languages

Available languages

Elbows:
45° elbows provide better airflow than 90° elbows.
Good
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Exhaust hoods:
Must be at least 12" (305 mm) from ground or any object that
may obstruct exhaust (such as flowers, rocks, bushes, or snow).
B
A
4"
(102 mm)
4"
(102 mm)
Recommended styles:
A. Louvered hood
B. Box hood
Better
4"
(102 mm)
2½"
(64 mm)
Acceptable styles:
C. Angled hood

Plan Vent System

Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
A
A . Dryer
B . Elbow
C . Wall
D . Exhaust hood
Standard exhaust installation with rigid metal vent
B
C
D
E
F
G
B
H
E . Clamps
F . Rigid metal or flexible metal vent
G . Vent length necessary to connect elbows
H . Exhaust outlet
9