2.2.2. Cooker hood connected to ventilation unit Open the boost flap when cooking and if necessary increase the power of the fans of Vallox 132 E at the ventilation switch of the cooker hood. Keep the cooker hood flap closed at other times.
Vallox 132 E model (electric post-heating) VALLOX 132 E comes standard with a 1200 W electric radiator (1) for heating supply air. The temperature of supply air is adjusted at the thermostat regulator (B) located inside the unit behind the cover plate.
Vallox 132 E VKL R to go down, the antifreeze thermostat (A) of the HR cell of Vallox 132 E stops the supply air fan. The preheating resistor (2) switches off when exhaust air temperature is by circa 3 °C higher than the value set for the thermostat.
2.6. Air filtering Air filtering Vallox 132 E has both extract and supply air filtering before the fans and the heat recovery cell. The unit comes standard with an F7 class fine filter (B), which captures fine dust, pollen and dust not seen to the eye, and a G3 class coarse filter (A) for insects and heavy pollen, for instance.
MAINTENANCE INSTRUCTIONS 3.3. Filter guard A filter guard is available for Vallox 132 E as an option. Its indicator normally lights up at speeds 3 and 4 when the filters are clean, and this does not require any maintenance activities.