Vallox 132 E Series Instructions For Use And Maintenance Manual

Vallox 132 E Series Instructions For Use And Maintenance Manual

Hide thumbs Also See for 132 E Series:

Advertisement

Quick Links

Vallox
132
E
© VALLOX • We reserve the right to make changes without prior notification
MODELS:
VALLOX 132 E
VALLOX 132 E VKL
• 1.09.410E
• 29.1.2010
• Code 3550 E
© VALLOX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 132 E Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vallox 132 E Series

  • Page 1 Vallox • 1.09.410E • 29.1.2010 • Code 3550 E © VALLOX MODELS: VALLOX 132 E VALLOX 132 E VKL © VALLOX • We reserve the right to make changes without prior notification...
  • Page 2: Table Of Contents

    NOTE! Never switch ventilation off, because ventilation keeps indoor air quality uniform and removes gases and dust emanating from the structures. © VALLOX • We reserve the right to make changes without prior notification...
  • Page 3: Three Questions About Ventilation

    Supply air to rooms Extract air to the unit Extract air to the unit Outdoor air to the unit Outdoor air to the unit Exhaust air outside Exhaust air outside © VALLOX • We reserve the right to make changes without prior notification...
  • Page 4: Initial Adjustment

    2.2.2. Cooker hood connected to ventilation unit Open the boost flap when cooking and if necessary increase the power of the fans of Vallox 132 E at the ventilation switch of the cooker hood. Keep the cooker hood flap closed at other times.
  • Page 5: Post-Heating

    Vallox 132 E model (electric post-heating) VALLOX 132 E comes standard with a 1200 W electric radiator (1) for heating supply air. The temperature of supply air is adjusted at the thermostat regulator (B) located inside the unit behind the cover plate.
  • Page 6: Antifreeze And Preheating

    Vallox 132 E VKL R to go down, the antifreeze thermostat (A) of the HR cell of Vallox 132 E stops the supply air fan. The preheating resistor (2) switches off when exhaust air temperature is by circa 3 °C higher than the value set for the thermostat.
  • Page 7: Heat Recovery Bypass

    2.6. Air filtering Air filtering Vallox 132 E has both extract and supply air filtering before the fans and the heat recovery cell. The unit comes standard with an F7 class fine filter (B), which captures fine dust, pollen and dust not seen to the eye, and a G3 class coarse filter (A) for insects and heavy pollen, for instance.
  • Page 8: Maintenance Instructions

    The filters, summer/winter damper and the heating radiator change places correspondingly. REMEMBER! Clean the filters at least twice a year. © VALLOX • We reserve the right to make changes without prior notification...
  • Page 9: Fans And Post-Heating Radiator

    C Put the hook of the front edge of the damper below the front edge of the collar. To detach the damper take the same steps in the opposite order. Pellin irrotus tapahtuu päinvastaisessa järjestyksessä. © VALLOX • We reserve the right to make changes without prior notification...
  • Page 10: Filter Guard

    MAINTENANCE INSTRUCTIONS 3.3. Filter guard A filter guard is available for Vallox 132 E as an option. Its indicator normally lights up at speeds 3 and 4 when the filters are clean, and this does not require any maintenance activities.
  • Page 11: Troubleshooting

    • If fan speed is 1 or 2, check the cleanliness of the filters and otherwise normally. adjustment value or fan speed is 3 or 4. the unit, and clean or replace the filters if needed. Also check the external grille. © VALLOX • We reserve the right to make changes without prior notification...
  • Page 12 VALLOX 132 E/VKL Vallox Oy • Myllykyläntie 9-11 • FI-32200 Loimaa • Tel. +358 10 7732 200 • www.vallox.com © VALLOX • We reserve the right to make changes without prior notification...