Alarm Mode

When a received code matches to your receiver Selcall ID the UH9060/UH9080 will
respond based on the Call Alarm mode.
Call Alarm - Auto mode (Default)
a) Transmit an Acknowledge tone to the Caller.
b) Emit CALL Alarm for 10 seconds only.
c) Resume Quiet condition automatically after 20 seconds if the call is not answered.
d) The Unit will start decoding again when the 20 second period elapsed and the call
remained unanswered.
Call Alarm - Continue mode
a) Transmit an Acknowledge Tone to the Caller.
b) Initially an alarm of four successive beeps is emitted for 20 seconds and then two
successive beeps every four seconds continuously unless answered.
c) The Quiet Condition is never resumed.
d) The Unit continues to check if incoming codes have your Receiver Selcall ID
even though the Quiet Condition is already opened. When detected, it will send an
acknowledge Tone to the caller and then resets the Call Alarm.
For both of the above mentioned modes, transmission by using the PTT
button is possible when the TSQ
NOTE
1. Switch Off the Power.
2. Press and hold [POWER] and [MENU]. The SELCALL Settings Menu will display
(no tone will sound).
3. Press [MENU] repeatedly to select the Alarm mode setting - which is indicated on
the display as AL.
4. Press [SCAN]
5. Press
/
to select the desired Alarm mode from AUTO or CONT.
6. Press [SCAN] to exit the setting.
7. Press and hold [ENTER], to save and exit programming mode.
Group Call Mode
The Group Tone period can be adjusted to increase the ability to identify group calls.
Group 01 mode sets the tone period to 1 tone period (default). Group 02 mode sets the
1. Switch Off the Power.
2. Press and hold [POWER] and [MENU]. The SELCALL Settings Menu will display
(no tone will sound).
3. Press [MENU] repeatedly to select the Group Call mode setting - which is indicated
on the display as GROUP.
4. Press [SCAN]
5. Press
/
to select the desired Group Call mode from 01 or 02.
6. Press [SCAN] to exit the setting.
7. Press and hold [ENTER], to save and exit programming mode.