Group Scan (GS) Mode Priority Watch Busy Channel Lockout Call Tone Roger Beep Key Beep On/Off Internal Speaker Setting On/Off Mic Gain Setting Backlight Color Backlight Brightness Operation - Special Features Channel Banks 100 User programmable RX channels UNIDEN UH9000 UHF CB Transceiver...
Page 3
Search Extra Channel Range and Programme a RX Channel CTCSS Codes Table DCS Codes Table Channel Bank List - Police (POL) Channel Bank List - Fire UHF CB Channel Guidelines UHF CB Channels & Frequencies Warranty UNIDEN UH9000 UHF CB Transceiver...
Introduction The Uniden UH9000 is designed to provide you with years of trouble free service. Its rugged components and materials are capable of withstanding harsh environments. Please read this Operating Manual carefully to ensure you gain the optimum performance of the unit.
If there is trouble with transmitting: Check that the transmission line (coaxial cable) is securely connected to the ANTENNA connector. Check that the antenna is fully extended for proper operation. Check that all transmission line (coaxial cable) connections are secure and free of corrosion. UNIDEN UH9000 UHF CB Transceiver...
Removable Bracket & with fuse Washer Stars And Screws Screws Optional Accessories • UHF Antenna • External Speaker Visit the UH9000 page on the website for more information on the availability of optional accessories: www.uniden.com.au for Australia UNIDEN UH9000 UHF CB Transceiver...
Disconnecting the MIC from the MIC Jack Pull back the rubber cover and move it down along the cord. Using the flat blade of a screwdriver or similar object carefully push the lock tab of the MIC plug towards the MIC cord and at the same time tug on the MIC cord to draw back the MIC plug. UNIDEN UH9000 UHF CB Transceiver...
(not supplied) High quality Double-Sided tape can be found at good retail stores. Secure the front and back pieces of the MIC Hanger using the supplied binding screws. Locate a suitable mounting position. Apply high quality Double-Sided tape onto the flat area of the MIC Hanger back piece and then press firmly to the mounting position. UNIDEN UH9000 UHF CB Transceiver...
Align the guide rails along the side of the base and insert them into the slots provided. Then use the screws to lock them securely in position. BASE unit with secured guide rails. UNIDEN UH9000 UHF CB Transceiver...
Page 13
Slide Mount Bracket Slide the bracket along the guide rails to attach the bracket to the unit. Over the BASE unit Under the BASE unit UNIDEN UH9000 UHF CB Transceiver...
Operation Turning on the Power Press and hold rotary knob. Low-Voltage/High-Voltage Alert The UH9000 can operate on 12VDC (13.8V) or 24VDC (27.6V) power supply, with the range between 10.8VDC to 28.8VDC. If the power supply voltage exceeds approx. 30VDC, an alert tone sounds and HI flashes for 5 seconds. The power source must not exceed 32VDC otherwise permanent damage may occur to your radio, which may not be NOTE covered by the manufacturer’s warranty. If the input voltage falls below approx. 10VDC, LO flashes for 5 seconds. The power turns off automatically if voltage falls below 9.0VDC.
Setting the Squelch Level Press once, SQL shows and the current squelch level will flash. Turn the rotary knob or press to select the desired squelch level. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH9000 UHF CB Transceiver...
Then carefully turn through. the rotary knob clockwise until the noise fades. Now only strong signals get through. Monitor Press and hold the squelch and receive all weak signals. Press and hold again to cancel. UNIDEN UH9000 UHF CB Transceiver...
34 - page 40. For Australia, Channels 05 and 35 are reserved for Emergency Calls. NOTE Smart-Key Function The smart key [S] provides one touch access to one of these functions; Instant Channel, Call Tone or Equalizer. Press and hold [S] to change the SMART key function between the three options. UNIDEN UH9000 UHF CB Transceiver...
2. Turn the rotary knob at the base or press on the microphone to select the desired channel. 3. Press and hold to save and exit. Recalling the Instant Channel Press [S] when Smart Key is set to Instant Channel function. UNIDEN UH9000 UHF CB Transceiver...
Press [TRIPLE] to switch Triple watch On/Off. • Every 1.5 seconds the Instant channel is monitored for 40msec. • Triple watch function stops temporarily when receiving a signal. NOTE • Triple watch function is invalid in Scan mode. Transmitting The UH9000 transmits only on UHF-CB Channels. For your reference a list of the available channels, corresponding frequencies and guidelines for their use and selection is printed on page 34 - page 40. For Australia, Channels 05 and 35 are reserved for NOTE Emergency Calls. Select the desired channel. Press the microphone’s [PTT] button and speak normally into the microphone.
Select desired channel. 1. Press 4 times. The Scramble setting flashes. 2. Turn the rotary knob or press on the microphone to change the setting between OFF, 1 (Scramble-1), 2 (Scramble-2). 3. Press and hold to save & exit from the menu mode. For safety purposes Scramble is invalid on channel 5, 11, 22, 23, 35, Extra RX, Police and Fire (Channel 22 & 23 is valid in NZ) NOTE UNIDEN UH9000 UHF CB Transceiver...
CH02 on Duplex Mode will Receive on CH02 but Transmit on CH32 etc... If you transmit on CH01 Duplex mode, you are actually transmitting on CH31 the repeater station down-converts your signal and retransmits on CH01. Operation with the aid of a Repeater Station (Duplex). UNIDEN UH9000 UHF CB Transceiver...
41 - 48). 3. Press to store the setting. 4. Press and hold to save & exit the menu mode. Only channels 01 - 08 and 41 - 48 are available for Duplex. • Check with your local Retailer for information on available repeaters. NOTE UNIDEN UH9000 UHF CB Transceiver...
There are 3 scanning modes; Open Scan (OS), Group Scan (GS) and Master Scan (MS) During SCAN the UH9000 only checks channels or frequencies that are in the SCAN Memory, which are indicated by the M (memory) icon (●). The UH9000 maintains two SCAN Memories; one for Open Scan (OS) mode and the other for Group Scan (GS mode, to give you flexibility and allow you to use the radio more effectively.
P-: Master Scan is ON with the current GS channel memory. Open/Group Scan is disabled. P1: Master Scan is ON with loading CH09-20 in GS. P2: Master Scan is ON with loading CH21-30, 39, 40 in GS. P3: Master Scan is ON with loading CH49-60 in GS. P4: Master Scan is ON with loading CH61-70, 79, 80 in GS. UNIDEN UH9000 UHF CB Transceiver...
To select OS Scan Mode: 1. Press 9 times. The SCAN setting flashes. 2. Turn the rotary knob or press on the microphone till OPEN flashes and press to save scan type setting. 3. Press and hold to save and exit from the Menu mode. UNIDEN UH9000 UHF CB Transceiver...
Priority Channel for activity while listening to the active one. To select GS Scan Mode: 1. Press 9 times. The SCAN setting flashes. 2. Turn the rotary knob or press on the microphone till GROUP flashes and press to save scan type setting. 3. Press and hold to save and exit from the Menu mode. UNIDEN UH9000 UHF CB Transceiver...
ON or OFF. 3. Press and hold to save & exit from the menu mode. If SCAN is deactivated while it is tuned to an active channel, the UH9000 will stay on that active channel. If none of the channels are active, the UH9000 will reinstate the scan start channel. NOTE If OS/GS Scanning is initiated when there are no channels programmed in OS/GS memory, an error tone will be heard and scanning will not start (see Add/Remove Channels from SCAN Memory, page 23). NOTE Busy Channel Lockout If the channel is already in use, you can prevent the UHF CB Radio from transmitting .
15 times. The BEEP setting flashes. 2. Turn the rotary knob or press on the microphone to change the setting between OFF, 1, 2, 3... 7. 3. Press and hold to save & exit from the menu mode. UNIDEN UH9000 UNIDEN UH9000 UHF CB Transceiver UHF CB Transceiver...
2. Turn the rotary knob or press on the microphone to select the color from CLEAR/ BLUE / RED / PURPLE/ GREEN / CYAN / YELLOW. 3. Press and hold to save & exit from the menu mode. UNIDEN UH9000 UHF CB Transceiver...
Operation Backlight Brightness 1. Press 19 times. The BRIGHT setting flashes. 2. Turn the rotary knob or press on the microphone to change the setting between Off (oF), 1(Lo), 2(mid) and 3(Hi). 3. Press and hold to save & exit from the menu mode. UNIDEN UH9000 UHF CB Transceiver...
Operation - Special Features Channel Banks The UH9000 has three banks (groups) of channels to select from; CB UHF CB + User programmable RX channels¹ POL (Police) Pre-programmed Police frequencies² FIRE Pre-programmed Fire & Ambulance frequencies² When the POL is showing then pre-programmed police channels will be available.
Operation - Special Features 100 User Programmable RX Channels The UH9000 has 100 receive only channels (CH81 to CH180) which can be programmed with frequencies ranging from 400-520MHz (in 12.5kHz steps). The extra RX channels only appear, as part of the CB channel bank, when a frequency has been programmed to a channel. There are two ways to programme RX channels;...
Operation - Special Features Search Extra Channel Range and Programme a RX Channel UH9000 can search extra channel range (400MHz-520MHz) per 12.5KHz step. Then you can store the stay frequency to extra channel. Turn power off Press and hold while turning power on (pressing rotary knob).
The above situations are not a fault of the radio but a symptom of mixed wideband and narrowband radios in current use. It is expected that as older wideband radios are phased out this issue will be eliminated. UNIDEN UH9000 UHF CB Transceiver...
Warranty UNIDEN UH9000 UHF CB Transceiver IMPORTANT: Satisfactory evidence of the original purchase is required for warranty service Please refer to our Uniden website for any details or warranty durations offered in addition to those contained below. Warrantor: The warrantor is Uniden Australia Pty Limited ABN 58 001 865 498 (“Uniden Aust”). Terms of Warranty: Uniden Aust warrants to the original retail purchaser only that the UH9000 UHF CB Transceiver (“the Product”), will be free from defects in materials and...
Page 42
Product, together with satisfactory evidence of your original purchase (such as a legible copy of the sales docket) to Uniden. Please refer to the Uniden website for the address details. You should contact Uniden regarding any compensation that may be payable for your expenses incurred in making a warranty claim. Prior to delivery, we recommend that you make a backup copy of any phone...