JTS RU-988KB Instruction Manual page 21

Uhf pll, remoset u ultrasonic synchronizing technology
Table of Contents

Advertisement

◎ SQ Receiving sensitivity
-5~+10dB, press
the ▲/▼ key to
select SQ
◎ Digital Code (Digi Code)
dC On
dC OFF
Note: In the digital code start mode, the
microphone should wait for a few seconds to be
turned on until the receiver finishes decoding.
If not activated, LCD screen will show warning
words (frequency and dC OFF flash in turn)
Select TX Transmitter
◎ ATT. Microphone audio input attenuation
At OFF
Audio input without attenuation
At On
Audio input attenuates at 20dB (de-
pending on whether the transmitter
has this function)
◎ Microphone Input Sensitivity
Normal
sensitivity
17
-5 most sensitive
+10 least sensitive
Default value 0
Turns on the digital code function
Turns off the digital code function
GAIN:+15dB
GAIN:+12dB
GAIN:+9dB
GAIN :+6dB
GAIN:+3dB
GAIN:0dB
GAIN:-3dB
GAIN:-6dB
GAIN:-9dB
GAIN:-12dB
GAIN:-15dB
The chart SQ is in 0dB(default value).
Indicates: The function is off.
Indicates: The mic input sensitivity is set as
0dB(default value).