Procedure
1.
2.
3.
Removing
1. Remove all cables connected to the X-300.
2. Use a screwdriver to lever down the spring catch of the device and pull the lower part of the
device away from the rail.
3. Remove the device from the upper edge of the DIN rail.
5.5

Wall mounting

Wall mounting
1. For wall mounting, use suitable mounting fittings for the wall
(for example, for a concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws 3.5
mm diameter and 40 mm long).
2. Connect the electrical cable connecting cables.
SCALANCE X-300M PoE
Compact Operating Instructions, 11/2019, A5E02630810-13
On the rear of the housing, there are two recesses. Place these
on the top edge of the DIN rail.
Then press the housing against the DIN rail until the spring catch
of the device locks onto the lower edge of the DIN rail.
Secure the cable for the power supply and the data and any other
cables required (for example for the signaling contact) according
to the descriptions in the section "Connecting up".