Activating Capacitive Loads; Reference Values For 787-1668 And 787-1668/0106-0000; Reference Values For 787-1668/0006-1000; Table 17: Standard Reference Values For 787-1668 And 787-1668/0106-0000 - WAGO EPSITRON 787-1668 Series Manual
Pos : 52 /Serie 787 (EPSITRON)/F unkti ons besc hrei bung/Ei nsc hal ten von kapaziti ven Las ten 787- 166x @ 12\mod_1341401971175_21.doc x @ 98843 @ 233 @ 1
6.3
Activating Capacitive Loads
High capacitive loads can be applied using the electronic circuit breaker. The
power supply unit providing power to the device must be capable of supplying a
voltage of at least 18 VDC, even at the maximum required current. The required
current can be set using the rotary switch.
The tables below gives some standard reference values determined in experiments
with 24 VDC input voltage:
6.3.1
Reference Values for 787-1668 and 787-1668/0106-0000
Table 17: Standard reference values for 787-1668 and 787-1668/0106-0000
Line lengths
(m) for feed
and return
lines
0
2.5
5.0
10.0
20.0
40.0
* Capacities determined with a base load of 10 A/6 A at the output channel.
6.3.2
Reference Values for 787-1668/0006-1000
Table 18: Standard reference values for 787-1668/0006-1000
Line lengths
(m) for feed
and return
lines
0
2.5
5.0
10.0
20.0
40.0
* Capacities determined with a base load of 6 A at the output channel.
Pos : 53 /Serie 787 (EPSITRON)/F unkti ons besc hrei bung/Betri ebs zus tände, Sig nalisi erung, R eaktionen 787- 166x @ 12\mod_1341474059753_21.doc x @ 98960 @ 2 @ 1