Instruction book
temperatures and time settings are correct. Check that all control and shut-down devices are fitted and
that they function correctly. If removed, check that the coupling guard of the vacuum pump drive shaft
has been reinstalled.
16. Every time the separator element is renewed, examine the discharge and the inside of the oil separator
vessel for carbon deposits; if excessive, the deposits should be removed.
17. Protect the motor, air filter, electrical and regulating components, etc. to prevent moisture from entering
them, e.g. when steam cleaning.
18. Make sure that all sound damping material and vibration dampers, e.g. damping material on the
bodywork and in the air inlet and outlet systems of the vacuum pump are in good condition. If
damaged, replace it by genuine material from the manufacturer to prevent the sound pressure level
from increasing.
19. Never use caustic solvents which can damage materials of the air net, e.g. polycarbonate bowls.
20. Faults or wearing of seals may cause oil lubricant leaks. Avoid dispersion in soil and pollution of other
materials.
6996 0224 30
Also consult sections
Safety precautions during installation
during operation.
These precautions apply to machinery processing or consuming air or inert gas.
Processing of any other gas requires additional safety precautions typical to the
application which are not included herein.
Some precautions are general and cover several machine types and equipment;
hence some statements may not apply to your machine.
Some precautions are general and cover several machine types and equipment;
hence some statements may not apply to your machine.
and
Safety precautions
11
Need help?
Do you have a question about the GVS 16A and is the answer not in the manual?