Download Print this page

Procedure To Remove Compressor - Daikin R42NUY14 Service Manual

Removal procedure 4/5/6/6.5/7 hp class, outdoor unit, non-inverter, pair type, cooling only
Hide thumbs Also See for R42NUY14:

Advertisement

Procedure to Remove Compressor

5. Procedure to Remove Compressor
Procedure
Step
Removing top panel and
front panel according to
the "Procedure to
Remove Outside Panels".
Dismount 5 screws to
1
remove the stop valve
mounting plate.
2
Disconnect the gas
piping and the liquid
piping.
To remove the terminal
3
cover, press the
protruded section on
both right and left sides.
Disconnect the lead
4
wires from the
terminals.
Dismount the 3 nuts
5
fixing the compressor.
6
Disconnect 3 brazed
joints.
Lift and take out the
compressor.
6
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Stop valve
mounting plate
Screws
Compressor
fixing nut
Check that the refrigerant is
completely discharged
before starting the
disassembling work.
Color of terminal end
R36NU
RED
R36~51NU
RED
Brazed joints
(3 joints)
1 of compressor fixing nuts
is outside of the partition
plate.
Si241313
Points
BLK
C
M
S
WHT
BLK
W
U
V
WHT
Removal Procedure

Hide quick links:

Advertisement

loading