Download Print this page

Procedure To Remove Compressor - Daikin R18NUV2S Removal Procedure

Outdoor unit
Hide thumbs Also See for R18NUV2S:

Advertisement

Si241319

4. Procedure to Remove Compressor

Procedure
Step
Removing top panel and
front panel according to
the "Procedure to
Remove Outside Panels".
To remove the terminal
1
cover, press the
protruded section on
both right and left sides.
Disconnect the lead
2
wires from the
terminals.
Dismount the 3 nuts
3
fixing the compressor.
4
Disconnect 3 brazed
joints.
5
Lift and take out the
compressor.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Compressor
fixing nut
Procedure to Remove Compressor
Brazed joints
(3 joints)
Stop valve
mounting plate
Points
Check that the refrigerant is
completely discharged
before starting the
disassembling work.
Color of terminal end
R18 • 24NUV2S
(C)
BLU
(S)
YLW
(R)
RED
1 of compressor fixing nuts
is outside of the partition
plate.
5

Advertisement

loading

This manual is also suitable for:

R24nuv2s