Summary of Contents for peerless-AV DS-LEDP Series
Page 1
DS-LEDP Series *Actual confi guration may vary 2017-02-13 #:146-9011-4 (2018-03-02)
Page 2
WARNING ENG - This product is designed to be installed on unistruts. Before installing make sure the supporting surface will support the combined load of the equipment and hardware. Screws must be tightly secured. Do not overtighten screws or damage can occur and product may fail. Never exceed the Maximum Load Capacity. Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
Parts (Before beginning, make sure you have all parts shown below). Parts List Description Part # scissor A corner bracket kit KIT-LED001-2 mechanism kit corner bracket asy wood screw B extrusion connector kit KIT-LED004A-2 extrusion connector asy C corner adaptor kit KIT-LEDADP-XXXA-2 top corner bracket asy bottom corner bracket asy...
Page 4
corner bracket extrusion cross tube connector kit support bracket kit corner adaptor side adaptor kit top center bottom center adaptor kit adaptor kit horizontal extrusion kit spacer kit tube kit 2017-02-13 #:146-9011-4 (2018-03-02)
Page 5
Refer to layout drawing included for your specifi c model. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 6
Left column Insert corner brackets and support brackets into extrusion and tighten screw to lock channel nut in place. A (2) H (2) ENG Channel nut must start ENG Tighten screw to lock in vertical position. channel nut. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 7
Middle columns Insert corner brackets and support brackets into extrusion and tighten screw to lock channel nut in place. A (4) H (2) ENG Channel nut must start ENG Tighten screw to lock in vertical position. channel nut. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 8
Right column Insert corner brackets and support brackets into extrusion and tighten screw to lock channel nut in place. A (2) H (2) ENG Channel nut must start ENG Tighten screw to lock in vertical position. channel nut. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 9
Optional: Use extrusion connector if provided. Tighten connecting hardware. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 10
Secure right vertical column onto both horizontal columns. Tighten corner bracket hardware. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 11
Outside spacer (G) Inside spacer (G) Slide on columns, spacing and securing one at a time. Tighten corner bracket hardware. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 12
Insert adaptors into extrusion and tighten screws to lock channel nuts in place. Refer to layout drawing included with your model for appropriate spacing. ENG Channel nut must start ENG Tighten screw to lock in vertical position. channel nut. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 13
Adjust adaptor and support bracket height. Refer to layout drawing included for appropriate spacing. L bracket must be fl ush with bottom of extrusion. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 14
Tighten all adaptor bracket and support bracket hardware. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 15
ENG Fully extend and bolt into place for installation only. Hand tighten. Unbolt and close after installation. J (2) 2017-02-13 #:146-9011-4 (2018-03-02)
Page 16
WARNING ENG - When installing Peerless wall mounts to P1000T unistrut metal framing channels, the channels must be installed and supported per the Unistrut design specifi cations. Use only compatible Unistrut hardware. Never exceed maximum load capacity of Unistrut channel or supporting surface. Unistrut not included.
Page 17
Unistrut hardware not included. 1/4" (6mm) Low profi le: 5/16-18 x 3/4" (M8 x 20mm) bolt Standard profi le: 5/16-18 x 3/4" (M8 x 20mm) bolt J (2) 2017-02-13 #:146-9011-4 (2018-03-02)
Page 18
Unistrut hardware not included. Do not tighten screws. Low profi le: 5/16-18 x 3/4" (M8 x 20mm) bolt Standard profi le: 5/16-18 x 3/4" (M8 x 20mm) bolt 2017-02-13 #:146-9011-4 (2018-03-02)
Page 19
I (2) 7/16" (11mm) 2017-02-13 #:146-9011-4 (2018-03-02)
Page 23
10-1 ENG Use hardware provided with adaptor kits. 1/4" (6mm) 10-2 ENG Level display on Y and X axis. Tighten connecting hardware after attaching each display. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 24
10-3 ENG Level displays on Y and X axis. Tighten connecting hardware after attaching each display. 10-4 ENG Level displays on Y and X axis. Tighten connecting hardware after attaching each display. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 25
10-5 ENG Level displays on Y and X axis. Tighten connecting hardware after attaching each display. ENG Optional: loosen screws to remove screens. 2017-02-13 #:146-9011-4 (2018-03-02)
Page 26
ENG Unbolt and close after installation. Remove J (2) 2017-02-13 #:146-9011-4 (2018-03-02)
LIMITED FIVE-YEAR WARRANTY Peerless Industries, Inc. (“Peerless”) warrants to original end-users of Peerless ® products will be free from defects in material and workmanship, under normal use, for a period of fi ve years from the date of purchase by the original end-user (but in no case longer than six years after the date of the product's manufacture).
Page 28
Peerless-AV Peerless-AV Europe Peerless-AV de Mexico 2300 White Oak Circle Unit 3 Watford Interchange, Ave de las Industrias 413 Aurora, IL 60502 Colonial Way, Watford, Herts, Parque Industrial Escobedo Email: tech@peerlessmounts.com WD24 4WP, United Kingdom Escobedo N.L Mexico 66062 Ph: (800) 865-2112...
Need help?
Do you have a question about the DS-LEDP Series and is the answer not in the manual?
Questions and answers