  • Page 4: User Manual

    User Manual 1 .1 System overview The ECtemp 850 IV system is capable of keeping outdoor areas free of ice and snow. The ECtemp 850 IV can handle up to 2 independent areas, in any of the following combinations: • Single roof system...
  • Page 5 For more information please refer to the sensor manual. For more information about the ice and snow melting function of the ECtemp 850, please refer to: Appendix B: “How it works”. 08097083 / VIMHE202 © Danfoss | 2019.07 | 5...
  • Page 6: General Use

    System A and System B. The ECtemp 850 gives the user the oppor- tunity to view the current status of the systems. The status can be shown in 2 different ways. 6 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 7  Please note, that only a few of the menus for each system are shown! For a complete overview of the menu system, please refer to Appendix A: “Menu sys- tem”. 08097083 / VIMHE202 © Danfoss | 2019.07 | 7...
  • Page 8: Possible Alarms During Operation

    Not all error prone sensors can be discovered using this fea- ture! Solution: - Acknowledge error and go to “Installer Site” in the menu system and select “Change System”. - Contact your local service centre to get a replacement. 8 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 9: Changing Parameters And Performance Of Systems

    It is possible to enable and disable the “Clogged drain warning”. The factory setting is “Warning On”. System and sensor name It is possible to change the names of the system and connected sensors (see Appendix A: Installer menu). 08097083 / VIMHE202 © Danfoss | 2019.07 | 9...
  • Page 10 It is possible to enable and disable the “Clogged drain warning”. The factory setting is “Warning On”. System and sensor name It is possible to change the names of the system and connected sensors. 10 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 11: Installer Manual

    (Refer to Technical Specification for power demand of sensors). • Ground and/or roof sensor(s) • Be aware of maximum number and cable length of sensors on each power supply (Refer to sensor manual for a more detailed description). 08097083 / VIMHE202 © Danfoss | 2019.07 | 11...
  • Page 12: Placement

    • When used as a dual system, only the sensors for System A can be connected. For connection of System B please refer to chapter: “Installation of dual system”. 4. Connect the power supply to mains. 12 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 13 Installation instruction ECtemp 850 IV Fig . A — Connection of ECtemp 850 IV DEVIbus sensors White White Black White White Black DC output DC supply – – – 13 14 15 16 17 18 19 20 21 22 23 24...
  • Page 14 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 K1= 1 x ln K1= 1 x ln 230 V cables 230 V cables 14 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 15 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 max. 15 A max. 15 A 230 V cables 230 V cables 08097083 / VIMHE202 © Danfoss | 2019.07 | 15...
  • Page 16: Installation Steps For System/Systems

    Please follow the general description and finally select the installation scenario accord- ing to the system type. Change setting with key: Accept setting with key: General Power on ECtemp 850 IV WELCOME TO ECTEMP 850 IV Select language SELECT LANGUAGE: ENGLISH System is being checked…...
  • Page 17 If for some reason you do not wish to configure the system now you can press to skip configuration of system. PRESS  TO END Press to end configuration. CONFIGURATION. 08097083 / VIMHE202 © Danfoss | 2019.07 | 17...
  • Page 18 If for some reason you do not wish to configure the system now you can press to skip configuration of system. PRESS  TO END Press to end configuration. CONFIGURATION. 18 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 19 SYSTEM B sensors… SCANNING... Wait until correct number of sensors for System B SYSTEM TYPE: is found. GROUND 3 GROUND SENSORS Press when all sensors for System B are FOUND. ACCEPT? found… 08097083 / VIMHE202 © Danfoss | 2019.07 | 19...
  • Page 20 Please refer to “Changing parameters and performance of systems” in “User Manual” for description of the configurable parameters. PRESS  TO END Press to end configuration. CONFIGURATION. 20 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 21 System is being scanned to find type of connected SCANNING... sensors… Select system type. SYSTEM TYPE: GROUND Wait until correct number of sensors for System B 1 GROUND SENSOR is found. FOUND. ACCEPT? 08097083 / VIMHE202 © Danfoss | 2019.07 | 21...
  • Page 22 Please refer to “Changing parameters and performance of systems” in “User Manual” for description of the configurable parameters. PRESS  TO END Press to end configuration. CONFIGURATION. 22 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 23: Modification Of System(S)

    1 SENSOR(S) Message is shown for 3 seconds. REACTIVATED! If no new sensors are found, it is reported to the user. NO GROUND Message is shown for 3 seconds. SENSORS FOUND! 08097083 / VIMHE202 © Danfoss | 2019.07 | 23...
  • Page 24 SENSOR? is found or “Cancel add sensor?” is selected. If the user selected a new sensor to add, the sensor SENSOR ADDED! is added. 24 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 25: Technical Specifications

    2 (domestic use) Controller type: Software class: Storage temperature: –20 °C to +65 °C Mounting method: DIN rail * For further information on the sensors please refer to the sensor manual. 08097083 / VIMHE202 © Danfoss | 2019.07 | 25...
  • Page 26: Factory Settings

    Melting temperature 4.0 °C 1.0 °C to 9.9 °C Post-heat 1 hour 0 to 9 hours Clogged drain On/off System mode Automatic • Automatic • Constant ON (manual timer) • Manually OFF 26 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 27: Appendix

                         Installer menu         08097083 / VIMHE202 © Danfoss | 2019.07 | 27...
  • Page 28                                  28 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 29            Change system  View statistics                08097083 / VIMHE202 © Danfoss | 2019.07 | 29...
  • Page 30                                30 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 31                                 08097083 / VIMHE202 © Danfoss | 2019.07 | 31...
  • Page 32: B: How It Works

    If the reason for ending a heating period is a decrease of moisture to below the cho- sen level the post-heating period will start. Post-heating ensures that no ice and snow is left on the roof. 32 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 33 If the temperature rises more than 1.5 °C above the chosen melting temperature the system will automatically stop heating the area irrespective of the moisture on the area. 08097083 / VIMHE202 © Danfoss | 2019.07 | 33...
  • Page 34 90 minutes and then turned off for 90 minutes. This entails that measurement of temperature can be up to 3 hours delayed. With more than one sensor this performance is significantly improved. 34 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 35 This will give relatively low energy consumption, but the area may remain wet and icy in short periods. The factory settings are average values providing a relatively high degree of security and moderate energy consumption. 08097083 / VIMHE202 © Danfoss | 2019.07 | 35...
  • Page 36: C: Psu And Feeder Cable

    13 14 15 16 17 18 19 20 21 22 23 24 ECtemp 850 IV 24 V DC 24 V DC 1 2 3 4 5 6 7 8 9 10 11 12 220–240 VAC 220–240 VAC 50–60 Hz 50–60 Hz 36 | © Danfoss | 2019.07 08097083 / VIMHE202...
  • Page 37 Installation instruction ECtemp 850 IV 08097083 / VIMHE202 © Danfoss | 2019.07 | 37...
  • Page 38: Warranty

    Installation instruction ECtemp 850 IV Warranty At Danfoss, we find it of great importance to deliver problem with your Danfoss product, you will find high quality products with long lasting effects. that Danfoss offers Danfoss warranty from the date of purchase on the following conditions:...
  • Page 39 The Danfoss warranty is granted to: Name: Address: Postal code: Phone: Please observe! In order to obtain the Danfoss warranty, the following must be carefully filled in. See other conditions on previous page. Electrical Installation by: Installation date: Type of thermostat: Production code:...
  • Page 40 Installation instruction ECtemp 850 IV 40 | © Danfoss | FEC | 2019.07 08097083 / VIMHE202...

Table of Contents