Fb161: Mobile Panel Status (F_Fb_Mp) - Siemens Second Wind Function Manual

Fail-safe operation of the mobile panel 277f iwlan
Table of Contents

Advertisement

Example application
Read Application example: Safety Functions (Page 113) if you use F_FB_RNG_n.
You can find another detailed example application in the Internet under
"http://support.automation.siemens.com", contribution number 25702331.
F I/O DB
An F I/O DB is automatically generated in HW Config for every F I/O.
Emergency stop button not evaluated
Keep the default setting for the output PASS_ON = 0 in the F I/O DB of the HMI device,
otherwise the emergency stop will not be evaluated.
The access to the F I/O and working with the F I/O DB is described in detail in the manual
"SIMATIC S7 Distributed Safety Configuration and Programming", "F I/O Access" section.
4.4.3

FB161: Mobile Panel Status (F_FB_MP)

Structure
Fail-safe operation of the Mobile Panel 277F IWLAN
Function Manual, 08/2008, 6AV6691-1FQ01-2AB0
WARNING
Configuration
4.4 S7 Distributed Safety
63