Technical data

9.3 Charging station

9.3
Charging station
Weight
Weight without packing
Supply voltage
Nominal voltage
Range, permissible
Transients, maximum permissible
Time between two transients, minimum
Current consumption with Mobile Panel
Current consumption with Mobile Panel and batteries in
charging compartment
Fuse, internal
Connection to the power supply
The charging station is connected to the power supply using the cable box which is included
in the scope of supply via a three-conductor flexible cable (0.75 mm²). Additional information
can be found in the operating instructions for the HMI device.
112
Typical
Constant current, maximum
Power on current surge I
2
Typical
Constant current, maximum
Power on current surge I
2
t
t
Approx. 1.1 kg
+24 VDC
19.2 V to 28.8 V (–20%, +20%)
35 V (500 ms)
50 sec
Approx. 1.5 A
Approx. 1.8 A
Approx. 1.7 A
s
2
Approx. 2.8 A
Approx. 3.4 A
Approx. 1.7 A
s
2
Electronic
Fail-safe operation of the Mobile Panel 277F IWLAN
Function Manual, 08/2008, 6AV6691-1FQ01-2AB0