installation manual
psH 30 - 200 tm
Theappliancemustbeconnectedtothepowersupplytakingthe
applicableinstallationinstructionsandtherelevantstandardsandre-
gulationsintoconsideration.Itisparticularlyimportanttoobservethe
"Regulationsforinstallinghigh-voltagesystemswithratedvoltagesup
to1000V"andregulationsfromthelocalpowersupplycompany.The
appliancesareonlydesignedforpermanentconnectiontoa230V~
ACnetwork.Forthis,installanisolatorthatdisconnectsallpolesofthe
powercablewithatleast3mmcontactseparation(e.g.fuse).
Electrical connection should be carried out by an authorised
!
fitter only.
Whendelivered,thePSH30...200wall-mountedstorageheatersare
wiredinthewayshownincircuitdiagram2.
Initial Start-up
Thespecialisttechnicianmustmonitortheappliancewhenitisputinto
operationandheatswaterforthefirsttime.
Maintenance
Theoutsideofthestorageheaterdoesnotrequireanyspecialmainte-
nance.Toclean,wipeusingasoftclothordampspongeonly.Donot
useanyabrasiveagentsoraggressivedetergents.
Caution! Always fully disconnect the appliance from the power
!
supply before carrying out any maintenance work.
Technical specifications
Type
Ratedvoltage
powerconsumption
Nominalcapacity
Powerconsumptioninstand-by
mode
Drawablequantityofmixed
water
    at40°C
(1)
Weight(empty)
Weight(wet)
Dimensions
A

B

C

D

E

H

I

K

M

X
Permissibleoperatingpressure
Degreeofprotection
Markofconformity
Cold water inlet 15 °C and cylinder temperature 65 °C
(1)
www.stiebel-eltron.com
PSH
30TM
50TM
W
2000
2000
Liter
30
50



kWh/d
0,73
0,93






Liter
56,2
101,5
kg
16
21
kg
46
71
mm
100
100
mm
296
296
mm
47
47
mm
390
390
mm
530
591
mm
585
840
mm
102
296
mm
386
386
mm
78
78
mm
G1/2"
G1/2"
MPa
Toensurealongservicelife,itisrecommendedtohaveaspecialist
technicianinspecttheanti-corrosionanode(magnesiumanode)inthe
applianceonceperyear.Thischeckmayneedtobecarriedoutmore
frequentlyinareaswithparticularlyaggressivewater–askthefitteror
yourlocalwatersupplycompanyforinformation.
Theapplianceisprotectedagainstoverheatingbyasafetytemperature
limiterwhichinterruptsallphases.Ifthesafetytemperaturelimiterhas
beentriggered,anauthorisedspecialisttechnicianisrequiredtocarry
outtherepairwork.Thehighlimitsafetycut-outcanberesetbypres-
singthepushbutton(markedSafety)onthecontrollerbelowthecontrol
panelcover.
Dimensions 4
Dimensionsofstorageheater(seetable"Technicalspecifications")
1 Heatingflange
2 Magnesiumanode
3 Deliverypipe
4 Temperatureselectionknob
5 Mountingbracket
6 Signallamp
Installation
type 3
1 Safetyvalve
2 Non-returnvalve
3 Pressuretestconnection
4 Stopvalve
5 Pressurereducer
6 Drawingpoints
7 Drainoutlet/siphon
80TM
100TM
120TM
1/N/PE~230V
2000
2000
80
100


1,16
1,48




144,3
186
26
30
106
130
100
100
274
274
28
28
470
470
583
735
810
962
255
255
485
485
75
75
G3/4"
G3/4"
G3/4"
0,6
Protectionagainstwaterjets(IP25)
Seeratingplate
150TM
200TM
2000
2000
2000
120
150
200


1,71
2,01
2,90




227,9
291
385,3
34
41
50
154
191
250
100
100
100
274
274
274
28
28
28
470
470
470
889
1125
1425
1116
1352
1652
255
255
255
485
485
485
75
75
75
G3/4"
G3/4"



7