CPI GRYPHON Operation And Service Manual page 26

Hide thumbs Also See for GRYPHON:
Table of Contents

Advertisement

Problem
Possible Causes
Checksum of
Error in coin validator's memory
validator
defective
No response
from validator
module
Tube sensors
Defective
Checksum of
changer
Defective
No response
from cash- less
system
No response
Bill validator does not respond to
from bill validator
coin changer commands as:
No
Hopper does not respond to coin
communication
changer commands as
with hopper
No
Recycler does not respond to
communication
coin changer commands as
with recycler
Payout jam in
Payout disc could not be driven
tube
from initial position as:
26
GRYPHON OPERATION AND SERVICE GUIDE
Communication with coin
validator interrupted
Coin validator defective
Filling level sensors
soiled
Filling level sensors
defective
Error in coin changer's
data memory
Card system does not
respond to coin changer
commands as not
connected correctly or
defective no longer
available
Not connected correctly
or defective
No longer available
Not connected correctly
or defective
No longer available
Not connected correctly
or defective
No longer available
Coin jam in payout area
Remedy
Check and correct coin validator
configuration
Remove rear cover from coin
changer, unfold coin validator
and check whether ribbon cable
is still connected correctly with
interface module (bottom PCB)
and coin validator
Replace coin validator
Remove coin jam
Clean coin path
Display coin validator diagnostic
screen, if necessary, contact
service technician
Check and correct coin changer
configuration in the settings menu
Check card system
Deactivate communication with
card system
Check bill validator
Deactivate communication with
bill validator
Check hopper
Deactivate communication with
hopper
Check recycler
Deactivate communication with
recycler
Remove coin cassette and then
jammed coin. Reinsert cassette
and pay out coin from relevant

Hide quick links:

Advertisement

Table of Contents

Troubleshooting