User Calibration Getting started with the Axicon verifier Configuring the Axicon Verifier AXICON SOFTWARE LICENCE AGREEMENT Axicon Software Licence Terms – Licence Grant Ownership of Software Copies of Software No Disassembly or Decryption of Software ...
Page 4
VERIFIER SERVICING & FACTORY RECALIBRATION (VCAS) Why CCD based verifiers require factory recalibration Axicon Factory Recalibration Service (VCAS) Other faults or damage Equipment Rental Scheme VCAS RECORD CONTACT US - 2 -...
Page 5
Compatibility), 73/23/EEC (Low Voltage), based on our own relevant test reports. Axicon Auto ID Ltd also certifies that this equipment, when used in conjunction with the latest verifier software has all of the features required to meet the 21CFR Part 11 standard.
Axicon Verifier quickly and easily. A full manual is available in electronic form on the software CD The Axicon Verifier is designed to work with any PC running a version of Microsoft Windows currently supported by Microsoft (some earlier versions may also be supported –...
Page 8
8. For further, detailed information, including a trouble-shooting guide, please read the manual which is available on the software CD. - 6 -...
Please ensure that the following items are present upon receipt. One of the following verifiers and the relevant cables: • Axicon 6000 Series – CCD verifier with USB cable attached. • Axicon 6500 Series – CCD verifier with USB cable attached.
The Install Program should now start automatically. (If not, open the CD using Windows Explorer and double-click the Autorun Program.) Click “Install Axicon Verifier” Follow the on-screen installation instructions for the next four windows (Select a language, Welcome, Software License Agreement and choose destination location) until you get to the “Select...
After installation is completed you will find the “Axicon Verifier” directory in “Start Menu/Programs” and a shortcut to the program on your desktop. • Double clicking the Axicon Verifier shortcut icon will now start the software. • Two windows will open: the Command window and the Summary window.
Page 12
These are available from Axicon on request. Manual installation/Updating of the USB drivers (if required) This section provides some guidance to users of the Axicon Verifiers who need to update the USB drivers. Firstly install the Axicon Verifier software (version 2.0.25.1 or later – note that it is always possible to download the latest software from our website).
Page 13
Have Disk button which will open the following dialogue. If the default installation location was chosen when the Axicon Verifier software was installed, then the appropriate driver files will have been copied to the location shown in the dialogue above.
Page 14
The Axicon Verifier software can now be launched and the software will find and connect to the verifier hardware.
INSTALLATION FOR APPLE MACINTOSH SOFTWARE 1. Insert the CD and double click on CD icon 2. Install USB Driver by double-clicking the USB Driver* icon. You will need an administrator password. Installer will need to restart your Mac after it has installed the driver. 3.
Take the calibration sheet out of the wallet and place it on a flat surface. For the Axicon 6000 Series use the EAN13 calibration code at the top left of the sheet. For the Axicon 6500 and 7000 Series use the large calibration code at the bottom of the sheet.
Page 17
After calibration is completed, store the calibration sheet in its wallet, away from light and physical damage. If your calibration sheet should ever become damaged or discoloured in any way, please contact Axicon or your supplier for a replacement. NB: During the calibration process the software displays the uncalibrated data and therefore reflectance values and grades displayed behind the calibration window can be ignored.
GETTING STARTED WITH YOUR AXICON VERIFIER In countries where Axicon offer training courses we would strongly recommend the use of these as the best way to get the most out of your verifier and to understand all of it’s features.
Page 19
This Summary Screen shows the overall print quality of the barcode as measured by the ISO/ANSI standards (the overall grade can be expressed either as a number (ISO) – or as a letter (ANSI) – this can be altered as required through the “Set-Up”...
Page 20
If the “Summary” Screen has shown poor print quality then the “Details” screen is the ideal point to initially see what went wrong with the barcode and hence focus the user on appropriate corrective action. The Scan Profile Screen…. Press to get:- The Scan profile screen shows the user exactly what the barcode will look like to a scanner.
accuracy – this screen will show the accuracy of the bar/space dimensions and highlight any problem areas. The Pass/Fail Screen…. Press to get:- This screen is ideal for users who need a quick visual indication of whether the barcode meets the right print quality standards.
Page 22
The user can select the pass/fail grade for other barcode types as specified either by an Industry Application Specification or by their customer. Magnification factor:- This remains for past support for Axicon customers who have model 5000 verifiers. For all others the settings in this field have no effect.
Page 23
Report Generator, although we do recommend that if you have any particular non-standard requirements these should be discussed with Axicon. The verifier can also be set to “Auto-print” in order to avoid a user forgetting to print a particular report.
Page 24
Features are included to stop users inadvertently or incorrectly using a wrong barcode for calibration purposes. Axicon recommend that under normal circumstances user calibration is carried out on a monthly basis (more frequently where there are high dust levels or significant changes in ambient temperature.
Page 25
Please do remember to keep a note of the password in a safe place. Remember: There are many great features in the Axicon verifier – this guide has been provided just to “Get you started”. We strongly advise all users to take advantage of the Axicon Training Courses (where offered) so that they can utilise all of the beneficial features of the verifier.
The transferee must accept these Licence Terms as a condition of the transfer. TERMINATION Axicon may terminate your Licence upon notice of failure to comply with any of these Licence Terms. Upon termination, you must immediately destroy the Software, together with all copies, adaptations and merged portions in any form.
However since we have no control over the circumstances in which you might use the Verifier you must satisfy yourself that the performance of the Verifier is suitable for your needs. Neither Axicon Auto ID Limited nor the vendor of this Verifier can accept any liability for any loss or damage (consequential or otherwise) which may be caused by use of this Verifier.
This is a Return to Bench warranty with shipping costs in one direction being borne by the customer/distributor. Should you need to return the unit to Axicon the original transit case (plus appropriate packaging) must be used. If the equipment is returned without the original transit case, Axicon will automatically charge an additional sum for the replacement of this case.
The availability of a swap-out unit to be used while the customer’s unit is being repaired. NOTE: Please see your Service Contract for full details including hire charges. For current cost of a Service Contract or equipment hire please contact either Axicon or your approved Axicon reseller. - 28 -...
Page 31
RECALIBRATION REQUIREMENT WHY DO CCD BASED VERIFIERS REQUIRE A FACTORY RECALIBRATION? Axicon 6000, 6500 and 7000 verifiers all use linear CCD sensors to capture scan reflectance profiles of barcodes. These CCD sensors work very much like digital cameras in the manner in which they capture an image, but they only image a single line scan across a barcode, similar to the scan line that you see with a hand held laser scanner.
Page 32
If this gradual dimming is not completely uniform then a factory recalibration would be required to re-establish the situation of creating uniform scan reflectance profiles from the scanning heads. If a uniform profile is not being achieved then a barcode symbol may start to achieve lower grades, particularly for modulation, than it should be getting.
Page 33
Should you decide not to take advantage of this service, we must remind you that Axicon Auto ID Ltd is unable to accept any responsibility for non- compliance to the appropriate GS1 STANDARDS once your verifier has exceeded the standard guarantee period provided on date of purchase.
EQUIPMENT RENTAL SCHEME Axicon Auto ID Ltd also offers an equipment rental scheme for customers who require replacement equipment for the duration of the service Please contact us for further details.
Page 35
For service and support in the Americas please log on to www.axicon.com for contact details Due to Axicon’s continuing product improvement programs, specifications and features herein are subject to change without notice. All trademarks are acknowledged as belonging to their respective companies.
VCAS SERVICE RECORD Verifier Model Serial Number Date Service Serial no. of Name & Undertaken calibration card Signature Verifier Documentation Booklet A x i c o n A u t o I D L i m i t e d Version 5 –...