Description Of Leds - Sony IXS-6700-C Installation Manual

Integrated routing system pack, integrated routing system
Table of Contents

Advertisement

1-10. Setting the On-Board Switches and Description of LEDs
n
The number shown in the parentheses ( ) indicates the address on the circuit board.
1. CA-65 board <IXS-6600/IXS-6700>
B
C
A
1
2
S1201
3
S1204
D1102
S1202
D1103
D1104
4
D1315
S1203
D1203
D1317
S1
D1001
S101
D1002
D1201
D1101
D1202
D1316
5
D1318
D201
D202
D203
D301
D302
D1313
D1311
D1309
6
D1314
D1312
D1310
D303
< LED >
D201 (A-5): EXTR ETHER 100/10
EXTR ETHER communication status indication.
Lights when the external communication network is
operating on 100BASE-TX.
D202 (A-5): EXTR ETHER LINK
EXTR ETHER communication status indication.
Lights when the connections between the related equip-
ment of the external communication network are estab-
lished (linked) normally.
D203 (A-5): EXTR ETHER ACT
EXTR ETHER communication status indication.
Lights when data are sent and received normally through
the data link using the external communication network.
D301 (A-6): INTER ETHER 100/10
Indication of the internal ETHER communication status
within own system.
Lights when the internal communication network within
own system is operating on 100BASE-TX.
D302 (A-5): INTER ETHER LINK
Indication of the internal ETHER communication status
within own system.
Lights when the connections between the related circuit
boards of the internal communication network are estab-
lished (linked) normally.
1-28
D
F
G
H
E
D2401
D2203
D2207
D2216
D1307
D1305
D1303
D1301
D1308
D1306
D1304
D1302
LE-264 Board
D1
D2
D3
ND1
K
L
M
J
D2215
D1319
D1320
D1504
D1503
D1502
D1501
S2401
D303 (A-5): INTER ETHER ACT
Indication of the internal ETHER communication status
within own system.
Lights when data are sent and received normally through the
internal data link using the internal communication network
within own system.
D1001 (A-5): REM1 A RX
REMOTE1 connector S-BUS data reception status indication
Lights for a period of 0.015 seconds when the system receives
data from the data link through the REMOTE1 A connector.
D1002 (A-5): REM1 B RX
REMOTE1 connector S-BUS data reception status indication
Lights for a period of 0.015 seconds when the system
receives data from the data link through the REMOTE1 B1
connector or B2 connector.
D1101 (A-5): REM1 C RX
REMOTE1 connector S-BUS data reception status indication
Lights for a period of 0.015 seconds when the system receives
data from the data link through the REMOTE1 C connector.
D1102 (A-5): REM1 A TX
REMOTE1 connector S-BUS data send status indication
Lights for a period of 0.015 seconds when the system sends
data to the data link through the REMOTE1 A connector.
P
R
N
D2214
D2208
D2201
D2217
D1801
IXS-6600/6700

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents