Precautions for connection
. For the controller and routing switcher that are used as the primary station, set the S/P selector switch
on the CPU board (on the CA board for the IXS-6700/IXS-6600) to the "P" position.
. For the controller and routing switcher that are used as the secondary station, set the M/S switch (S/P
selector switch in the IXS-6700/IXS-6600) on the CPU board (on the CA board for the IXS-6700/IXS-
6600) to the "S" position.
. A primary station can control up to 253 secondary stations.
. A single S-BUS line can be connected to up to 128 secondary stations.
. The maximum length of a single S-BUS line cable is 500 m (when the BELDEN 8281 cable is used).
. Terminate the T-type bridge that is connected to the last machine of the S-BUS line with a 75 Z
terminator. Also, terminate the unused REMOTE1 connector of each switcher with a 75 Z terminator.
. In the primary controller or routing switcher, two or more REMOTE 1 connectors can be used.
. In the secondary controller and routing switcher, only one REMOTE 1 connector can be used each.
How to use the T-type bridge
The B type of T-type bridge is supplied with the IXS-6700/IXS-6600. Prepare coaxial cable (BELDEN
8281) of 50 cm or less and use the T-type bridge as follows.
IXS-6700/IXS-6600
(rear panel block)
IXS-6600/6700
REMOTE1
(BNC-type connector, male)
BELDEN 8281 coaxial cable
(50 cm or less)
T-type bridge (B)
1-25