Installing Fluid Regulation Kit 222564
(Pump Model 231162)
WARNING
Before installing the fluid regulation kit, follow the
Pressure Relief Procedure on page 14. Discon-
nect all hoses from the pump.
Assemble the fluid regulation kit (66) as shown in
Detail A of Fig. 3. (Refer to the parts list on page 19.)
Install the mounting bracket (66k) on the regulator
(66f) using the two screws (66p) and lockwashers
(66q). Connect the fluid regulator and bracket to the
side of the cart (7) using the screw (66l), lockwasher
(66m) and nut (66n). Connect the 22" (560 mm) hose
(66h) to the outlet of the fluid filter (25).
DETAIL A
Fluid Regulation Kit 222564
includes items 66a–66q.
66d
66f
66e
66h
66b
66j
66k
66q
66p
1
Connect fluid hose here.
Fig. 3
Installation
1
66b
66c
66a
66l
66m
66n
66h (REF)
(SEE DETAIL A)
Connect the gun air supply hose (F) between the air
inlet of the gun (E) and the outlet nipple of the gun
(left) air regulator. See Fig. 2.
Connect the fluid hose (D) between the gun fluid inlet
and the outlet nipple (66b) of the fluid regulation kit.