18
PowerCombi Inverter/Charger
6
OPERATING INSTRUCTIONS
6.1
General
WARNING!
The PowerCombi Inverter/Charger must be properly assembled in accordance with the
Installation Instructions before it is used.
6.2
Main switch
The main switch on the PowerCombi Inverter/Charger has three positions: On (▬), Off () and
Remote (═).
WARNING!
Switching to Off or Remote does not cut off the connection to the batteries or the AC
source. This means that voltages are still present inside the apparatus!
Notes:
- Provided that the main switch is not in the Remote position, the PowerCombi
Inverter/Charger will switch on when a battery is connected and external AC power is
available, even if the switch is in the off position!
- If external AC power is unavailable or outside the specified limits, the PowerCombi
Inverter/Charger operates as an inverter.
- When using a PowerCombi Remote Control, switch to Remote.
6.3
Status LEDs
Battery Input voltage indicator
Output Load indicator
LED status
Voltage
< 11.0 V or >15.5 V
Red
Orange
11.0~ 11.5 V or 15.0 ~ 15.5 V
11.5 ~ 15.0 V
Green
LED status
Voltage
Red
> 115%
Orange
100 - 115%
Green
0 - 100%