Valor Retrofire RA24JDNK Installation & Owner's Manual

Gas conversion kits

Advertisement

Available languages

Available languages

INSTALLATION & OWNER'S MANUAL
Gas Conversion Kits RA24JDNK / RA24JDPK
This appliance is certifi ed for use from 0-4500ft. For
altitudes above 4500ft see local codes.

Kit Contents

• 1 Pilot injector (see chart below)
• 1 Burner
• 1 Main burner injector (see chart below)
• 1 Minimum rate by-pass screw (see chart below)
• 1 Set of conversion labels
• 1 Set of air shutters

Tools Required

• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small jewelers size fl at blade screwdriver, to set pressure
• Small fl at blade screwdriver, to release pressure tap on
valve
• Needle Nose Pliers, to remove by-pass screw
• Hex Allen wrench, 4 mm or 5/32", to remove pilot injector
• Special 2-pin screwdriver tip, supplied with kit, to
remove valve cover
• Manometer, to set pressure
Specifi cations
Fireplace Models
Gas
Altitude (Ft)
Input Max. (Btu/h)
Input Min. (Btu/h)
Manifold pressure (in w.c.)
Min. Supply pressure
(in w.c.)
Max. Supply pressure
(in w.c.)
Main Burner Injector
Pilot Injector
By-Pass Screw
4006631-01
© 2018 Miles Industries Ltd. All rights reserved.
Retrofi re
Use with Valor Retrofi re Heater Models RF24JD ONLY
RF24JDN
RF24JDP
Natural
Propane
0–4,500 Feet
20,000
18,000
6,500
12,500
3.2
9.5
5.0
11.0
10.0
14.0
82-580
92-200
35
27
185
125
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
Natural Gas Burner:
Has two interlaced rows of slots
Propane Gas Burner: marked "LPG"
Has single row of slots and two rows
of small holes

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Retrofire RA24JDNK and is the answer not in the manual?

Questions and answers

Summary of Contents for Valor Retrofire RA24JDNK

  • Page 1 INSTALLATION & OWNER’S MANUAL Retrofi re Gas Conversion Kits RA24JDNK / RA24JDPK Use with Valor Retrofi re Heater Models RF24JD ONLY This appliance is certifi ed for use from 0-4500ft. For WARNING altitudes above 4500ft see local codes. This conversion kit shall be installed by a Kit Contents qualifi...
  • Page 2 Conversion Procedure 6. Remove the 6 screws (2 underside of bracket) securing the burner brackets to the burner tray. 1. If the fi replace is already installed, remove window cover with barrier screen, window, and fuel bed. 2. Disconnect the gas inlet pipe from the inlet elbow fi...
  • Page 3 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com...
  • Page 4 FOYER À GAZ RADIANT Trousses de conversion de gaz RA24JDNK / RA24JDPK Utilisez avec les foyers Valor Retrofi re RF24JD SEULEMENT Cet appareil est certifi é pour utilisation de 0 à 4 500 AVERTISSEMENT pieds. Pour altitudes au-dessus de 4 500 pieds, consultez la réglementation locale.
  • Page 5 Procédure de conversion 6. Enlevez les 6 vis—dont 2 sous les supports— retenant les supports du brûleur à la plaque. 1. Si le foyer est déjà installé, enlevez le contour de fenêtre et pare-étincelles, la fenêtre, et le lit d’alimentation. 2.
  • Page 6 12. À l’aide de la lame d’un petit tournevis ou autre 15. Ouvrez l’alimentation de gaz et vérifi ez s’il y a des objet similaire, soulevez le capuchon de plastique fuites en utilisant une solution savoneuse. Les couvrant la vis de réglage de pression sur le devant pressions d’alimentation minimale et maximale sont de la soupape.