Cleaning And Care; Supplementary Accessories - Bosch MM100 Installation Instructions For Installers

Hide thumbs Also See for MM100:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
14 | Product details
Technical data
Permissible ambient
temperature
IP rating
for installation in heat
source
for wall-mounted
installation
Protection class
ID no.
Table 3
°C
°C
8
25065
38
14
19170
44
20
14772
50
26
11500
56
32
9043
62
Table 4
Test measurements for the flow temperature sensor
(included in scope of delivery)
2.4

Cleaning and care

▶ If required, wipe the enclosure with a damp cloth. Never
use chemically aggressive or acidic cleaning agents.
6 720 813 621 (2014/12)
0 - 60 °C
Determined by the IP rating
of the heat source
IP44
I
Data plate ( Fig. 18, page 97)
°C
7174
68
2488
5730
74
2053
4608
80
1704
3723
86
1421
3032
2.5

Supplementary accessories

For heating circuits with or without mixer:
– Heating pump; connection to PC1
– Flow temperature sensor – system for low loss header
(optional; not possible with all user interfaces);
connection to T0
– Temperature switch; connection to MC1; when limit
temperature is exceeded, power supply to terminal 63
- PC1 is interrupted; if there is no temperature switch in
the heating circuit without mixer or in the constant
heating circuit, connect jumper ( Fig. 1 [2],
page 91) to MC1 (included in standard delivery).
Additional accessories for heating circuit with mixer:
– Mixing valve actuator; connection to VC1
– Flow temperature sensor in assigned heating circuit;
connection to TC1
Additionally, for a constant heating circuit:
– External signal for heat requirement; connection to
MD1 (the pump is only switched on if the external heat
requirement is enabled on the user interface)
– Mixing valve actuator (optional); connection to VC1
– Flow temperature sensor in assigned heating circuit
(optional); connection to TC1
For cylinder primary circuit (e.g. after low loss header):
– Cylinder primary pump; connection to PC1; connect
jumper ( Fig. 1 [2], page 91) toMC1
– DHW circulation pump (optional); connection to VC1
(terminal 43: DHW circulation pump phase/terminal
44: not assigned)
– Flow temperature sensor for low loss header (optional;
not possible with all user interfaces); connection to T0
– Cylinder temperature sensor; connection to TC1.
Installation of additional accessories
▶ Install additional accessories according to legal
requirements and the instructions supplied.
MM100

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents