The valves are equipped with a manual override. Using this manual override,
the switching function of the valve can also be triggered if the valve solenoid is not
energized.
The manual override is only intended for manual operation. It is not suitable for
frequently recurring manual operations.
The manual override is located on the side of the valve solenoid facing away from the
valve.

10 Maintenance and repair

10.1 Cleaning and care

Penetrating dirt and fluids will cause faults!
When dirt and fluids penetrate, a safe function is no longer ensured.
Always ensure absolute cleanliness when working at the valve.
Solvents and aggressive, highly inflammable cleaning agents!
Aggressive cleaning agents may damage the seals and the surface of the valve and
cause them to age faster.
Never use solvents or aggressive or highly inflammable cleaning agents.
Damage to the hydraulic system and seals!
A high-pressure washer's water pressure could damage the hydraulic system and
the seals of the valve. The water displaces the hydraulic fluid from the hydraulic
system and seals.
Do not use a high-pressure washer for cleaning.
For cleaning and care of the valve, please observe the following:
Close all openings with appropriate protective caps/devices.
Check that all seals and caps of the plug-in connections are firmly fitted so that
no humidity can penetrate the valve during cleaning.
Remove external dirt and keep sensitive and important parts like valve solenoids
clean.
Remove dust and dirt accumulations from the valve at regular intervals.
RE23177-XH-B/05.21, .WE6..5X/...XM..., .WE6..5X/...XH... Bosch Rexroth AG