Debem TRP-EL Instructions For Use And Maintenance Manual

Debem TRP-EL Instructions For Use And Maintenance Manual

Industrial pumps

Advertisement

Quick Links

I
ISTRUZIONI PER L'USO E LA MANUTENZIONE
GB
INSTRUCTIONS FOR USE AND MAINTENANCE
TR 02/2017
INDUSTRIAL PUMPS - POMPE PER L'INDUSTRIA
petrochemical, food, mechanical, environmental, printing, chemical, painting, galvanic, textile and ceramic, industry
TR
ISTRUZIONI PER L'USO
I
E LA MANUTENZIONE
U S E A N D
GB
M A I N T E N A N C E
M A N UA L
TR-EL
TÜV NORD Italia
S.r.l.
TR-EL
TR-PN
www.debem.it

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRP-EL and is the answer not in the manual?

Questions and answers

Summary of Contents for Debem TRP-EL

  • Page 1 U S E A N D M A I N T E N A N C E M A N UA L TR-EL TR-PN TÜV NORD Italia S.r.l. ISTRUZIONI PER L’USO E LA MANUTENZIONE INSTRUCTIONS FOR USE AND MAINTENANCE www.debem.it TR 02/2017...
  • Page 2 Debem SRL 2017 I diritti di traduzione riproduzione e adattamento totale o parziale con qualsiasi mezzo sono vietate in tutti i paesi. Debem SRL 2017 All rights of total or partial translation, reproduction and adaptation by any means are reserved in all countries.
  • Page 3: Table Of Contents

    PUMP DESCRIPTION TECHNICAL FEATURES WARRANTY SAFETY RULES TRANSPORT AND POSITIONING CONNECTING THE PRODUCT CIRCUIT ELECTRICAL CONNECTION COMMISSIONING A PRODUCT CIRCUIT MAINTENANCE B LEAKAGE C INTERNAL CLEANING OF IMPELLER D CLEANING THE PRESSURE-RELIEF VENT TROUBLESHOOTING DECOMMISSIONING DEMOLITION AND DISPOSAL SPARE PARTS info@debem.it...
  • Page 4: Lettera Alla Consegna

    The residual risk during the operation is shown by special symbols with additional wording. The manual also uses pictograms that highlight and distinguish between certain details or suggestions given in order to ensure safe and correct operation of the pump. www.debem.it...
  • Page 5 EXTRAORDINARY OPERATIONS: indic operations to be carried out solely at the Manufacturer’s workshops by technical suppor info@debem.it...
  • Page 6: Identificazione Pompa

    FABRIQUE PAR - FABRICADA POR - HERGESTELLT VON - MANUFACTURED BY costruttivi della pompa al fine di determi- DEBEM SRL - Via del bosco 41 - 21052 Busto Arsizio (VA) - ITALIA DEBEM SRL - Via del bosco 41 - 21052 Busto Arsizio (VA) - ITALIA Il codice identificativo * che compare alla voce “TIPO”...
  • Page 7: Descrizione Pompa

    WARNING: - l’impiego a vuoto; stiche della pompa; pompa da travaso fusti TR differen- Debem stresses any use of the TR - l’impiego con liquidi da pompare incompatibili chimicamente - l’impiego con acque particolarme te da quanto precedentemente con i materiali di costruzione;...
  • Page 8 - use with products in suspension whose specific weight is greater than that of the liquid (e.g. water with sand); WARNING: Debem stresses any use of the TR drum - with product temperatures and characteristics of the pump; pump different from that stated above is considered - with water that is particularly hard and/ or full of deposits.
  • Page 9: Caratteristiche Tecniche

    NOMINALE” e “PREVALENZA max” sono mpaggio di acqua a 18°C con aspirazione e eri. TR - PN HNICAL SPECIFICATIONS ce data refer to standard installations. Flow Rate” and “MAX HEAD” values refer to water at 18°C with free-flow suction and Ø Ø info@debem.it...
  • Page 10 DATI TECNICI unità di TRP-EL TRF-EL TRA-EL TRP-PN TRF-PN TRA-PN this quali misura understa Motore pneumatico (potenza a 7 bar) manufac Attacco aria pollici skills in c Pressione aria Min - Max 2 - 7 2 - 7 2 - 7...
  • Page 11: Modalita' Di Garanzia

    - The Manufacturer accepts no liability for the costs and risks of ship- contained herein. ping defective, repaired or replacement parts, including any customs In the event of any dispute, the place of jurisdiction shall be duties that may apply. Busto Arsizio. info@debem.it...
  • Page 12 - check that the liquid to be pumped does not fall below or A- drain the product being pumped; exceed the minimum and maximum levels; - ensure that the treated liquid does not contain or is not ac- B- wash the inside with suitable (non- flammable) liquid; cessible to solid parts; www.debem.it...
  • Page 13: Prescrizioni Di Sicurezza

    DANGER OF DRUM OVERTURNING AND/OR PUMP DANGER OF POLLUTION, CONTAMINATION, INJURY CAPSIZING INTO THE TANK. AND/OR DEATH. info@debem.it...
  • Page 14: Trasporto E Posizionamento

    2 Prelevare il manuale d’uso e manu- descritto qui di seguito. 2 Prelevare il manuale d’uso e manu- descritto qui di seguito.
  • Page 15 C - make sure that the pump position. remains stable whilst running etta info@debem.it and is suitably anchored or CAUTION supported to prevent it from WARNING: Plastic pumps should never rest...
  • Page 16 60mm the pump motor upon reaching the minimum. C- prevedere un dispositivo di 1200mm livello che determini l’arresto www.debem.it del motore della pompa al di Transport and positioning are now sotto del livello minimo. complete. Il trasporto e posizionamento sono...
  • Page 17: Allacciamento Del Circuito Prodotto

    Manufac kinked; HOSES BURDEN THE info@debem.it VERSA. 3 Provvedere al montaggio del motore 3 Provvedere al montaggio del motore 3 Fit the motor to the pump body and 3 Fit the motor to the pump body and...
  • Page 18 5 Protect staff and surroundings by installing suitable protection power tighten the fixing nut. tighten the fixing nut. for containment and collection of the product in the event of unforeseen breakdowns and/or spillages, as well as convey- ets the www.debem.it...
  • Page 19 CONNECTION AND FILTRO OLIO ROTATION CHECK FILTER 1 Check that the filter is installed on The procedure for connecting a pump info@debem.it the motor exahaust port and fit if with pneumatic motor to the necessary. compressed-air circuit is as follows:...
  • Page 20 6.4 Repeat the checks detailed underpoint 5. WARNING: where the user foresees the risk of exceeding the temperature limits set out herein, it will be necessary to fit the system with a protective www.debem.it...
  • Page 21: Messa In Servizio

    Should either of these phenomena occur, stop the vent the product container or the pump itself from tipping over; pump immediately in order to ascertain and remove the cause of the abnormal behaviour. C- correctly immersed in the product (see minimum and maximum level). info@debem.it...
  • Page 22 WARNING: button or disconnecting the air check that the fluid being supply in the case of a pump with discharged contains no air or gas pneumatic motor. bubbles, otherwise stop the pump immediately and remove the causes. www.debem.it self...
  • Page 23: A Manutenzione Del Circuito Prodotto

    B- stop the pump using the controls (button for electric motor or manual valve for pneumatic motor); A1 Disconnect the pump from the motor power supply (electric or pneumatic). C- before starting work, put on suitable personal protective info@debem.it...
  • Page 24 HOLES AND SHORT-CIRCUIT OF ed il relativo pescante: PERICOLO ELECTRIC MOTOR. t n i t n I DI FUORIUSCITA DEL LIQUIDO DAI FORI DI VENTILAZIONE E CORTO www.debem.it CIRCUITO DEL MOTORE ELETTRICO. POMPA PLASTIC IN PLASTICA PUMP...
  • Page 25 B4 Replace the seal by referring to the o l l t n i t n I re alla sostituzione con ricambi originali. respective spare parts table. e l l info@debem.it t n i t n I ning product is s on the pump À POMPA...
  • Page 26 Cleaning of the pressure-relief vent is now complete. operation of the pump. D1 Carry out the operations described under Section A herein “PRODUCT CIRCUIT MAINTENANCE”. D2 Clean any impurities or deposits from the pump pressure- relief vent using a pin. www.debem.it...
  • Page 27 Cleaning of the pressure-relief vent is e-relief vent of the now complete. ore this operation egularly, every 40 sure correct erations described erein “PRODUCT ENANCE”. ties or deposits essure-relief vent in its normal ssure-relief vent is info@debem.it...
  • Page 28: Ricerca Guasti

    WARNING: for more serious problems, we strongly ised skilled maintenance engineers. In the event of abnormal recommend that you contact the DEBEM SERVICE behaviour and in order to fix faults, please refer to the following DEPARTMENT; our engineers will provide you with assistance as quickly as possible.
  • Page 29 4.4a Open the pump, remove the seal and check its condition. worn. 4.5 Bearings are worn. 4.5a Open the pump, strip the motor and check bearing play. 4.6 Installation not perfor- 4.6a Thoroughly recheck motor installation and electrical con- med correctly. nection. info@debem.it...
  • Page 30: Messa Fuori Servizio

    2 Smontare la pompa dal luogo di installazione. incidenti o danni diretti e/o indiretti. 3 Provvedere ad un idoneo trattamento e/o lavaggio interno www.debem.it Manufac...
  • Page 31: Parti Di Ricambio

    SPARE PARTS Details follow of the spares available for each TR pump model. Please provide the following information when ordering spares: this quali understa manufac id number part skills in c or repairs Type of pump Page Quantity Manufac info@debem.it...
  • Page 32 www.debem.it...
  • Page 33 MOTORE PNEUMATIC PNEUMATICO MOTOR À c i t c i t e l i e l i f l a n i l i t n c i f i t n c i f info@debem.it...
  • Page 34 Intermediate bush e l l Fermo ghiera Locknut retainer Ghiera collegamento Connecting locknut Supporto pompa Pump support Portagomma Hose barb f n i Guarnizione Gasket Tubo interno inferiore Lower inner tube Boccola centraggio centrale Middle centring bush Targhetta ID plate www.debem.it...
  • Page 35 Boccola intermedia Intermediate bush e l l Fermo ghiera Locknut retainer Ghiera collegamento Connecting locknut Supporto pompa Pump support Portagomma Hose barb Guarnizione Gasket t n i t n I Fermo boccola intermedia Intermediate bush retainer Targhetta ID plate info@debem.it...
  • Page 36 RIVENDITORI/RESELLERS: CENTRI DI ASSISTENZA/ASSISTANCE CENTERS: TIMBRO RIVENDITORE/RESELLER STAMP: Via Del Bosco, 41 - Busto Arsizio (VA) ITALY Tel. +39/0331/074034 - fax +39/0331/074036 info@debem.it - www debem.it...

This manual is also suitable for:

Trf-elTr seriesTrp-pnTra-elTrf-pnTra-pn

Table of Contents