Mounting on a Desk or Shelf
To mount the switch on a desk or shelf, complete the following steps.
1. Verify that the desk or shelf is sturdy enough to support the switch.
2. Attach the four adhesive rubber feet to the bottom of the switch.
f
CAUTION!
Desk, shelf, or wall mounting of the equipment should be such that the amount of air flow required for safe operation of the equipment is
not compromised. Allow 1-inch clearance on the top and sides of the unit for sufficient air flow.
Mounting on a Wall
To mount the switch on a wall, complete the following steps.
1. Using the mounting holes on the bottom of the unit as a template, install the user-supplied screws in the appropriate location on the
wall. Be aware of the dimensional limitations of the screws. Hang the switch on the screws and ensure that it is securely attached.
f
CAUTION!
The SDX 8110-24-740W must be mounted in the face down orientation when wall mounted.
g
NOTE
The wall mount brackets are not supplied with the unit and must be purchased separately from ADTRAN, part number 1700520F1.